7.1.2
Deleting alarm memory/LED test
1. Hold down button S1
2. Turn the knob anti-clockwise to Position 5
LEDs LD0 and LD1 flash
release button S1
3. Turn the knob to Position 4
4. Press button S1
all LEDS flash for 30 sec
7.1.3
Functional test cycle
7.1.3.1
Cycle setting
1. Hold down button S1
2. Turn the knob anti-clockwise to Position 5
LEDs LD0 and LD1 flash
release button S1
3. Turn the knob to Position 3
press button S1
the cycle starts: during its progress, the programme
behaves like a normal cycle
LED LD1 flashes
N.B.: at the beginning of the next programme after the test cycle, the resins are washed. The overall duration
of the cycle is approximately 50 minutes.
7.1.4
Quitting diagnostics mode
To quit diagnostics mode, press button S0 and turn off the appliance
or wait 60 seconds: the LEDS are turned on and the appliance is on stand-by awaiting your selection
SOE/PR
17
599 72 48-93