7 Service Mode Settings

Only if the appliance is on stand-by awaiting instructions, hold down the two configured buttons
simultaneously, turn on the appliance and wait for at least 4 sec.
With EDW1xxx-2G display boards: by pressing buttons S1+S3.
With EDW3xxx display boards: by pressing buttons S1+S3 (EDW2500) or S3+S4 (EDW2503).
7.1

EDW500

7.1.1

Diagnostics mode, alarm reading and testing

1. Hold down button S1
2. Turn the knob anti-clockwise to Position 5
LEDs LD0 and LD1 flash
release button S1
3. Press button S1
the first alarm stored is displayed: the Cycle end LED
flashes in sequence, interrupted by pauses, corresponding
to the alarm: for the alarm code, please see the alarms
summary table.
4. Press button S1 again to display the second alarm
5. Press button S1 once more to display the third alarm
6. Press button S1 for the fourth time to move on to enabling the appliance's actuators, the CYCLE END
LED is on:
4th activation: regenerating solenoid valve
5th activation: drain pump
6th activation: water fill to level solenoid valve
7th activation: heating (only if the level of water is reached)
8th activation: washing pump
9th activation: detergent/rinse aid dispenser
10th activation: drying fan (if turbo-dry)
7. All the positions can be repeated by pressing button S1 in sequence
The components are powered if the appliance door is shut: open the door to select another
actuator then shut it again.
If button S1 is not pressed for 60 seconds, you automatically quit diagnostics mode.