Description Of The Alarms - AEG EDW750 Service Manual

Proclean/reallife. edw5xx series; edw1xxx-2g series
Table of Contents

Advertisement

"i20" Code - family : Draining Problem
"i20"-Code : Fails to drain
Acoustic signal and visual alarm, depending on the appliance customization; the program can be
restarted.
The level switch restore point is not reached within the time limit set.
The time limit set starts when the drain pump is activated.
The time limit set is reset when the drain pump stops normally.
Time limit set: Normal 90 sec; Test cycle = 60 sec
"i30" Codes - family: Aqua Control
"i30" code: water detected from aqua control sensor
Acoustic signal and visual alarm, depending on the appliance customization; the program is restarted
automatically in this alarm condition.
If this alarm condition occurs, the drain pump is activated.
Time limit set: 10 sec.
"i40" Codes - family: Analogue pressure sensor problem
"i41" – code: No pressure sensor signal
the error is set if the sensor signal is lost for more than 1s
abort program and display error
"i42" – code: Calibration invalid, pressure signal too noisy
the warning is set if the sensor signal is not stable enough for calibration or if the signal is out of range
for an empty sump.
the signal noise level for calibration is defined in MCF
"i43" – code: Pressure sensor signal too high
the error is set if the sensor signal is out of range, signal high for more than 1 s
the signal range is defined in MCF
abort program and display error
"i44" – code: Pressure sensor signal too low
the error is set if the sensor signal is out of range, signal low for more than 1 s
the signal range is defined in MCF
abort program and display error