Edw503; Diagnostics Mode, Alarm Reading And Testing; Deleting Alarm Memory/Led Test - AEG EDW750 Service Manual

Proclean/reallife. edw5xx series; edw1xxx-2g series
Table of Contents

Advertisement

7.2

EDW503

7.2.1

Diagnostics mode, alarm reading and testing

1. Hold down the PROGRAMMES button
2. Turn the appliance on at the ON/OFF button
LED L1 flashes
LEDs L2 and L3 are turned on
3. Wait for LEDs L2 and L3 to be turned off
4. Press the PROGRAMMES button
the CYCLE END LED shows the first alarm stored with a sequence of flashes
5. Press the PROGRAMMES button twice more to display the other two alarms stored
the CYCLE END LED shows the alarms
6. From the 4th activation, the individual components testing begins according to the defined sequence
LED L2 is turned on permanently for the duration of the components test
4th activation: regenerating solenoid valve
5th activation: drain pump
6th activation: water fill to level solenoid valve (level of water reached)
7th activation: heating (only if the level of water is reached)
8th activation: washing pump
9th activation: detergent/rinse aid dispenser
10th activation: drying fan
11th activation: the cycle is repeated from the first alarm
All the positions can be repeated by pressing button S2 in sequence.
The components are powered with the appliance door open and shut.
If the PROGRAMMES button is not pressed for 60 seconds, you automatically quit diagnostics
mode.
7.2.2

Deleting alarm memory/LED test

1. Hold down the PROGRAMMES button
2. Turn the appliance on at the ON/OFF button
LED L1 flashes
LEDs L2 and L3 are turned on
3. Press the PROGRAMMES button before LEDs L2 and L3 are turned off
LED L2 flashes
LEDs L1 and L3 are turned on
4. Wait for LEDs L1 and L3 to be turned off
5. Press the PROGRAMMES button
all LEDs flash and the buzzer sounds