9 Alarm codes

9.1

Alarm Management

In "ProClean/RealLife" appliances, the alarm codes are defined in families of alarms and current alarms,
displayed as:
i = alarm indication
Caution:
Only the alarm family codes are displayed to the user.
The complete alarm code will be stored among the three alarms that can be stored by the appliance.
A new alarm code is only stored if it differs from the last one stored.
The three most recent alarm codes can be displayed only in Service Mode or using the Sidekick tool.
Appliances with a display will show the alarms by a number of flashes of the cycle end LD, such as in
"DIVA": i10=1 flash, i50=5 flashes, iB0=11 flashes
Alarm Code Description
"i10" Code - family : Water Tap Closed
"i10" code: during static filling
This alarm code is used to display problems with the water inlet tap being closed at the beginning of the
program. It is set up to detect problems during the static water filling. A drain phase is performed before the
error is displayed to the user.
Acoustic signal and visual alarm, depending on the appliance customization; the program can be
restarted.
The water level defined is not reached within the time limit set.
The time limit set starts when the fill solenoid valve is opened.
The time limit set is reset when the fill solenoid valve is closed.
The water will first be drained before an error is displayed to the user.
Time limit set: Normal 90 sec; Test cycle = 30 sec (times could differ as they are defined in the MCF)
"i11" code: during dynamic filling
Acoustic signal and visual alarm, depending on the appliance customization; the program can be
restarted.
The water level defined is not reached within the time limit set.
The time limit set starts when the fill solenoid valve is opened.
The time limit set is reset when the fill solenoid valve is closed.
The water will first be drained before an error is displayed to the user.
Time limit set: Normal 120 sec; Test cycle = 60 sec (times could differ as they are defined in the
washing cycle specifications)
SOE/PR
iXY
X = family of the alarm
29
Y = Current alarm
599 72 48-93