Functional Test Cycle; Reading Alarms And Activating Components - AEG EDW750 Service Manual

Proclean/reallife. edw5xx series; edw1xxx-2g series
Table of Contents

Advertisement

7.2.3

Functional test cycle

7.2.3.1
Cycle setting
1. Hold down the PROGRAMMES button
2. Turn the appliance on at the ON/OFF button
LED L1 flashes
LEDs L2 and L3 are turned on
4. Press the PROGRAMMES button twice before LEDs L2 and L3 are turned off
LED L3 flashes
LEDs L1 and L2 are turned on
5. Wait for LEDs L1 and L2 to be turned off
6. Press the PROGRAMMES button to start the test cycle
LED L4 is turned off
LED L2 flashes for the duration of the cycle
7.2.3.2
Cycle phases
Phase
Water fill, Turbo activation
Washing continuously, dispenser
opening
Drain
Water fill
Washing continuously
Drain
Water fill
Controlled washing at 2600 rpm,
heating at 60 ° C
Controlled washing at 2600 rpm,
temperature kept at 60 ° C
N.B.: at the beginning of the next programme after the test cycle, the resins are washed. The overall duration
of the cycle is approximately 50 minutes.
7.2.4

Reading alarms and activating components

Once in Service mode, the reading of alarms and the activation of individual components is possible using
button S1. After the last component in the list has been activated, the sequence will be repeated.
The sequence is defined as follows:
1. Alarm 1
2. Alarm 2
3. Alarm 3
4. Regenerating solenoid valve
5. Drain pump
6. Fill solenoid valve
7. Heating element (if the level of water is reached)
8. Washing pump (at 2800 rpm)
9. Detergent dispenser
10. Drying fan
If a display is available, the activated component is indicated by its own number in the list (starting with
number 4).
SOE/PR
Duration
30''
temperature
45''
dilution
---
60''
dilution
---
1200''
19
time
599 72 48-93