Motorola FX9500 Regulatory Manual page 9

Rfid reader
Hide thumbs Also See for FX9500:
Table of Contents

Advertisement

Regulatory Guide
9
US and Canada
To comply with FCC RF exposure requirements, antennas that are mounted
externally at remote locations or operating near users at stand-alone desktop of
similar configurations must operate with a minimum separation distance of 24cm
from all persons.
Power Supply
Use ONLY a LISTED Motorola, Type no. 50-14000 or PWRS-14000 (24 Vdc/3.25
A max), direct plug-in power supply, marked Class 2 or LPS (IEC60950-1, SELV).
Use of alternative Power Supply will invalidate any approvals given to this unit and
may be dangerous.
Battery
CAUTION Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Air Handling Space Applications
This device is suitable for use in Environmental Air Handling Space (EAHS) in
accordance with Section 300-22(c) of the National Electric Code, and Sections
2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 21, CSA
C22.1.
All Cables intended for interconnecting the FX9500 to other devices shall be
suitable rated for use in Environmental Air Handling Space per UL 2043.
Devices such as Power Adaptors, PoE (Power Injectors), antennas shall not be
installed in the Environmental Air Handling Space unless they are suitable for use
in the EAHS per UL 2043.

Advertisement

Table of Contents
loading

Table of Contents