Ipex Low Profile Vent Termination Kits - Rinnai RU80i Manual

Twin pipe pvc/cpvc venting guide for condensing tankless water heaters
Hide thumbs Also See for RU80i:
Table of Contents

Advertisement

Certified PVC/CPVC Vent Termination Options (continued)
3" and 4" Low Profile Vent Termination Kits
The following information should be used in conjunction
with the IPEX System 636 Installation Guide:
Termination kits are to be tested and certified for
use with the brand of pipe-fitting-cement system
that is to be utilized in the application. The IPEX
Low Profile termination is fully certified for use with
IPEX product only.
System 636 PVC Low Profile Vent kits are rated to
65°C maximum and are made from certified
compound.
All termination kits must be located and installed in
accordance with these instructions, local building
code, and CSA B149.1 Natural Gas and Propane
Installation Code.
Installation:
1. Once location is determined, cut 2 appropriately
sized holes in the wall to accommodate the pipe.
(Reference the Low Profile Termination Kit-
Dimensions table below)
2. Slide intake and exhaust pipes through the holes.
Secure (using solvent cement) both pipes to the
base of the vent termination kit. (Be sure to follow
guidelines for solvent cementing as described in
the System 696 Installation Guide)
3. Use the supplied screws and anchors to secure the
base to the wall. (a drilled 3/16" hole, 1-3/16" deep
will be needed for the anchors.) Use the base as a
template to locate the anchor hole.
4. Using the supplied screws, secure the Cap to the
Base.
5. Upon securing the vent termination and pipes, seal
the wall penetrations (from the interior) using a
PVC compatible sealant material.
All exhaust vents and air inlets must terminate at the
same height to avoid severe personal injury, death, or
substantial property damage.
Low Profile Termination Kits-Dimensions
Item #
Description
3" Flush Mount
196985
Vent Kit
4" Flush Mount
196986
Vent Kit
NOTICE
Pipe Outside
Hole Spacing
Diameter
(Ctr to Ctr)
3.5"
5.6"
4.5"
5.6"
Qty
1
1
8
4
To Water Heater Intake
From Water Heater
Vent Pipe Connection
Orientations
Air Piping
Vent Piping
Vent
19
Kit Contents
Item Description
Base (Two Holes)
Cap (One Hole)
Stainless Steel Screws
Plastic Anchors
Air Connection
Vent / Air
Termination
Grade or
Snow Line
Vent Base
12" Min Between Edge of Air
Inlet and Adjacent Vent Outlet
Air
Vent / Air
Termination
12"
min
to
overhang
12" min
Vent Cap

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ru98i

Table of Contents