BACKWASH
STEP 15CS
CYCLE 1
SET
REGENERANT DRAW DN
STEP 16CS
CYCLE 2
SET
BACKWASH
STEP 17CS
CYCLE 3
SET
RINSE
STEP 18CS
CYCLE 4
SET
FILL
STEP 19CS
CYCLE 5
SET
END
STEP 20CS
CYCLE 6
SET
FILL UNITS
STEP 21CS
LBS
SET
ALT FILL TRIGGER
STEP 22CS
REGENS
OFF
SET
ALT FILL AMOUNT
STEP 23CS
15.0
LBS
SET
19
STEP 15CS – Press the  or  buttons until selection of first cycle appears in left upper corner, in this
example BACKWASH is selected. Press NEXT to go to Step 16CS. Press REGEN to return to previous
step.
STEP 16CS – Press the  or  buttons until selection of second cycle appears in left upper corner, in
this example Regenerant Draw DN is selected. For a H151 control valve: prior to selecting DN or UP or
not selecting a regenerant flow cycle, verify the correct valve body, main piston, regenerant piston and
stack are being used and the injector or injector plug(s) are in the correct location. Press NEXT to go to
Step 17CS. Press REGEN to return to previous step.
STEP 17CS – Press the  or  buttons until selection of third cycle appears in left upper corner, in this
example BACKWASH is selected. A second backwash mode is recommended on iron applications > 1.0
ppm. Press NEXT to go to Step 18CS. Press REGEN to return to previous step.
STEP 18CS – Press the  or  buttons until selection of fourth cycle appears in left upper corner, in this
example RINSE is selected. Press NEXT to go to Step 19CS. Press REGEN to return to previous step.
STEP 19CS – Press the  or  buttons until selection of fifth cycle appears in upper left corner. Press
NEXT to go to Step 20CS. Press REGEN to return to previous step.
STEP 20CS – Press the  or  button until last regeneration cycle; END appears (up to 9
regeneration modes are possible). End must be selected as last cycle. Press NEXT to go to Step
21CS.
STEP 21CS – Press the  or  button to select "LBS" or MIN as brine tank fill units. Select LBS with
standard 0.5 gm brine refill flow control. Select minutes if using larger brine refill flow control. Factory
setting is LBS.
STEP 22CS – Press the  or  button to select number of standard regenerations which would trigger
one alternate brine fill amount. Range: 1-99. Factory setting is Off. Press NEXT to go to Step 23CS.
STEP 23CS – Select amount of salt to be used when alternate regeneration requested. This screen is
not displayed if off is selected in previous step. Softener Range 0.1–200 lbs. Filter Range 0.05–20.0
Gallons.