RELAY 1 "TIME"
STEP 10S
TRIGGER
SET
RELAY 1 SET POINT
10
MIN
SET
RELAY 1 DURATION
3:00
MIN
SET
RELAY 1 "GALLONS"
STEP 13S
TRIGGER
SET
RELAY 1 SET POINT
1
SET
GAL
RELAY 1 DURATION
0:01
MIN
SET
RELAY 1 "REGEN GALLONS"
STEP 16S
TRIGGER
SET
12
STEP 10S – Set Relay to activate by Time, Gallons, Regen Gallons, Off or Service Alarm by using 
or  buttons. A relay can be used to operate a chemical feed pump or solenoid. The choices are:
• Relay Triggered on Time - Relay activates after set number of minutes after start of regeneration. Start of
regeneration is defined by first backwash cycle, dn brine or up brine, whichever is first.
Relay deactivates after set time. (Range: 0 – 500 minutes)
• Relay Triggered on Gallons - Relay activates every set number of gallons while in service and deacti-
vates after set time. (Range: 0.1 – 20,000 gallons)
• Relay Triggered on Regen Gallons - Relay activates after set number of gallons in service or gallons
used during regeneration and de-activates after set time or when meter stops registering flow, which-
ever comes first. (Range: 0.1 –20,000 gallons)
• Service Alarm - Relay activates on service alarm setting: gallons, time or both, see step 21S.
• Relay Triggered for Lock Out - Relay activates after set number of minutes into regeneration. A zero
or positive start time references the first backwash or brine cycle as start. "Regen" can be selected
for time setting to activate relay for entire regeneration cycle; 2 minutes before and 1 minute after.
"Regen" can be selected as lockout setpoint by pressing down arrow through all negative numbers.
(Range -20 – 500 minutes)
• Off - If off is selected, Steps 11S – 21S will not be shown. Factory setting = OFF. Press NEXT to
go to step 11S or other selection for relay settings, or 20S if OFF selected.
STEP 11S – If off was selected in previous step, this screen does not appear.
STEP 11S
If Time chosen to Activate Relay, use up and down arrows to set # of minutes AFTER START OF
REGEN to activate relay. Start of regeneration is defined as first Backwash or Regenerant Draw
mode. Press NEXT to go to Step 14S.
STEP 12S – Use Up and Down arrows to set duration of relay activation in minutes.
STEP 12S
Time Range = Negative 20 minutes to a positive 500 minutes. Press NEXT to go to Step 20S.
Press REGEN to return to previous step.
STEP 13S – Gallons chosen to activate relay. If Off or Time was selected in previous steps, this screen
does not appear. Press NEXT to set # of gallons per relay activation.
STEP 14S – Use up and down arrows to set # of gallons per relay activation.
STEP 14S
Range = 0.1–20,000 gallons. Press NEXT to set duration of relay activation.
STEP 15S – Use up and down arrows to set duration of relay activation in minutes.
STEP 15S
Range = 1 second - 500 minutes (0:01–500:00). Press NEXT to go to Step 16S.
Press REGEN to return to previous step.
STEP 16S – If REGEN gallons chosen to activate relay. Relay activates after set number of gallons
have been used in service or during regeneration and then deactivates after set period of time or after
flow stops, whichever comes first. Range = 0.1–20,000 gallons. Press NEXT to go to Step 17S.