Hellenbrand H-151 Series Owner's Manual page 13

Water conditioning system
Table of Contents

Advertisement

RELAY 1 SET POINT
1
SET
RELAY 1 DURATION
0:01
SET
RELAY 1 SERV ALARM
STEP 19S
TRIGGER
SET
RELAY 2 TRIGGER
STEP 20S
REGEN
GAL
SET
SERVICE ALARM
STEP 21S
BOTH
SET
SCHEDULED SERVICE
STEP 22S
0.25
YR
SET
SCHEDULED SERVICE
STEP 23S
80000
GAL
SET
RETURN TO NORMAL MODE
13
STEP 17S – Use up and down arrows to select number of gallons per relay activation of regen
STEP 17S
gallon setting. Range: 1 -100 gallons. Press NEXT to go to Step 18S.
GAL
STEP 18S –
STEP 18S
and down arrows to set duration of relay activation in minutes. Range = 1 second - 500 minutes.
MIN
Press NEXT to go to Step 19S. Press REGEN to return to previous step. Meter does not read
during regeneration.
STEP 19S
If Service Alarm chosen to activate relay, relay closes whenever Service Alarm has triggered.
Programming for relay closure on service reminder is done on Step 24S. Relay opens when
service alarm reset. Press NEXT to go to Step 20S to set Relay 2 Settings. If off selected for
Relay 2, Press NEXT to go to step 22S for service reminder programming.
• Relay closes on Gallons
• Relay closes on Time
• Relay closes on Both
• Off
STEP 20S –
Relay 2 programming includes identical options as Relay 1 with the addition of the ability
to trigger Relay 2 in Error Mode. Relay closes when ever control enters Error Mode and immediately
deactivates when error resolved and control reset. Press NEXT to go to Step 21S.
SERVICE REMINDER
STEP 21S – Set scheduled service display using  or  buttons. Available options are OFF, TIME, ON GAL
or BOTH. Selecting OFF disables this feature. If OFF is selected, press NEXT to exit System Setup. If
TIME, ON GAL or BOTH is selected press NEXT to select the TIME and/or ON GAL values. See Steps 24S
and/or 25S. This can also activate relay if Service Alarm is selected on Step 19S. Press REGEN to return
to the previous step.
STEP 22S – Service alarm for TIME ranges from 0.25 to 9.75 years. Use  or  buttons to select length
of time between service reminders. Press NEXT to either exit System Setup or if BOTH was selected go
to Step 23S. Press REGEN to return to the previous step. When time selected and # of days drops below
1 year, the next display will show "scheduled service in XXX days" after screen where service reminder is
programmed.
STEP 23S – Service alarm for ON GAL ranges from 100 to 9,999,000 gallons. Hold  or  buttons until
display flashes "SET" before releasing to select values. Press NEXT to see "Gallons until service" displays.
Press NEXT to exit system. Press REGEN to return to the previous step.
Reset service reminder by holding down up and down arrows together when reminder is displayed.
If Off or Time was selected in previous steps, this screen does not appear. Use up