Hellenbrand H-151 Series Owner's Manual page 11

Water conditioning system
Table of Contents

Advertisement

BACKWASH TIME
STEP 3S
10:00
SET
MIN
DRAW TIME
STEP 4S
60:00
SET
MIN
RINSE TIME
STEP 5S
6:00
SET
MIN
FILL
STEP 6S
30.0
LBS
SET
GRAIN OF CAPACITY
STEP 7S
84.0
SET
x1K
RESERVE CALCULATOR
STEP 8S
AUTO
SET
DELAY + IMMEDIATE
STEP 9S
REGEN
SET
11
STEP 3S – Select the time for the first cycle (which in this example is BACKWASH) using the
 or  button. Press NEXT to go to Step 4S. Press REGEN to return to the previous step.
STEP 4S – Select the time for the second cycle (which in this example is dn BRINE) using the
 or  button. Press NEXT to go to Step 5S. Press REGEN to return to the previous step.
STEP 5S – Select the time for the third cycle (which in this example is RINSE) using the  or
 button. Press NEXT to go to Step 6S. Press REGEN to return to the previous step.
STEP 6S – Select the time for the fourth cycle (which in this example is FILL, setting is
changed by lbs. of salt entered) using the  or  button. Factory setting is Medium Salting,
See page 38-39. Press NEXT to go to Step 7S. Press REGEN to return to previous step.
STEP 7S - Set Grain Capacity using the  or  button. The ion exchange capacity is in
grains of hardness as calcium carbonate for the system based on the pounds of salt that will be
used. The allowable grains capacity range varies from 5,000 to 500,000 grains. The increment
increase is 500 for the range from 5000 to 50,000; 1000 for the range of 50,000 to 200,000; and
2000 for the range of 200,000 to 500,000. Grains capacity is affected by the fill time. The grains
capacity for the selected lbs. salting should be confirmed by testing. The capacity and hardness
levels entered are used to automatically calculate reserve capacity when gallon capacity is set
to AUTO. Factory setting is the capacity of the softener at medium salting. See Page 34.
Press NEXT to go to Step 8S. Press REGEN to return to previous step.
STEP 8S – Set Gallons Capacity using  or  button. If value is set to:
• "AUTO" gallon capacity will be automatically calculated and reserve capacity will be automati-
cally estimated;
• "oFF" regeneration will be based solely on the day override set (see Installer Display/Settings
Step 3, page 9 / proportional brining will not function if OFF selected); or
• as a number of gallons (allowable range 20 to 250,000) regeneration will be based on the value
specified.
Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000 and 500
for the range of 10,000 to 50,000 and 2000 for range of 50,000 to 250,000.
If "oFF" or a number is used, hardness cannot be set in Installer Displays/Settings Step 2 I,
page 9. See page 32 for more detail. Factory Setting is AUTO. Press NEXT to go to Step 9S.
Press REGEN to return to previous step.
STEP 9S – Set Regeneration Time Options using the  or  button. If value is set to:
• "DELAY" means regeneration will occur at the preset time; if control is set as Twin Alt, alternation
will occur on zero, but regeneration is delayed to preset time.
• "IMMEDIATE" means regeneration will occur immediately when the gallons capacity reaches 0
(zero); or
• "DELAY + IMMEDIATE" means regeneration will occur at one of the following:
- the preset time when the gallons capacity falls below the reserve or the specified number of
days between regenerations is reached, whichever comes first; or
- immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See page 32 for more options. Factory Setting is DELAY + IMMEDIATE. If control is set as Twin
Alternating, this option is not available. Press NEXT to go to Step 10S. Press REGEN to return to
previous step.