CLEANING INSTRUCTIONS
Cleaning the Faucet and Sight Gauge - As Needed
1
Unscrew the handle/bonnet assembly and remove. Inspect the seat cup for wear.
Replace the seat cup if it is damaged. Clean the parts with a mild detergent solution.
Rinse, dry and reassemble the handle/bonnet by hand.
2
Remove the hose on top of the gauge (if applicable) by pulling it up and off of the
cap. Remove the gauge cap and the glass tube. Inspect the glass tube for cracks or
chips.
WARNING - If the gauge glass is broken, carefully inspect and remove all traces
of glass and insert a new glass tube, then thoroughly rinse out the faucet shank.
3
Clean the glass tube with a gauge brush soaked with a mild detergent solution. Rinse
and dry.
4
Clean the washers, rinse and dry.
5
Reassemble and hand tighten the cap.
Sight Glass Disassembly -
* Hose used only on models with aeration feature
FAUCET/GAUGE, CLEANING INSTRUCTIONS
Hose*
Cap
Washer
Glass
Shield
varies
Washer
Standard Type
Faucet Disassembly