Table of Contents INSTALLATION PREPARATION ................ 1 Basic Requirements ..........................1 Installation Check ..........................1 Cable Preparation ..........................1 1.3.1 Cable Lowest Specification Requirement ................1 1.3.2 Select Needed Power Supply Cable According to Transmission Distance ....2 SPEED DOME INSTALLATION ................3 Check Accessories ..........................
Page 3
2.7.2 Speed Dome Cable ........................10 2.7.3 Install the speed dome ........................12 WALL-MOUNTED BRACKET INSTALLATION ..........15 Mounting Component and Dimension ....................15 Installation Steps of Wall-mounted Bracket ..................16 3.2.1 Installation Conditions ........................ 16 3.2.2 Installation Steps .......................... 16 HANG-MOUNTED BRACKET INSTALLATION ..........
Page 4
APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION ..... 28 Outdoors ............................... 28 Indoors ..............................29 APPENDIX Ⅱ ABOUT RS485 BUS ..............30 RS485 Bus Main Feature ........................30 RS485 Bus Transmission Distance ....................30 The Problem in Practical Use ......................30 RS485 Bus FAQ ..........................
Page 5
13 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN DC 48V CABLE DIAMETER AND THE TRANSMISSION DISTANCE ..............36 14 APPENDIX IV WIRE GAUGE REFERENCE SHEET ........37...
Page 6
Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!
Important Safeguards and Warnings Safety Measures 1. Qualified Engineer Needed The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate. The installation engineer or maintenance engineer shall have qualification certificate for work at height.
Page 8
Please turn off the power and unplug the power cable, If there is any smoke, disgusting smell, or noise. Please contact your local retailer or customer service centre for help. All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair.
Page 9
Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning liquid to clean the shell and then use soft cloth to make it dry. Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result in shell transfiguration or paint flake.
1 Installation Preparation 1.1 Basic Requirements All installation and operation here should conform to your local electrical safety codes, fire protection regulations and relevant regulations. Make sure if the application scenarios of speed dome conforms to the installation requirements.
1.3.2 Select Needed Power Supply Cable According to Transmission Distance Refer to appendix Ⅲfor AC 24V power supply device. Refer to appendix Ⅳ for DC 12V power supply device. Refer to appendix Ⅴ for DC 24V power supply device. Refer to appendix Ⅵ for DC 36V power supply device. Refer to appendix Ⅶ...
2 Speed Dome Installation 2.1 Check Accessories Before installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are included. 2.2 Open the Device Please open the box and then take out the speed dome. See Figure 2-1. Figure 2-1 Note: ...
Page 13
2.3.1.1 Analog Speed Dome Dismantle the bracket component and you can see there are two DIP switches on the PTZ mainboard. You can use them to set speed dome address, baud rate and parity. Please refer to Figure 2-2 for the location of DIP switch. Figure 2-2 2.3.1.2 HDCVI Speed Dome Dismantle the bracket component and you can see there are two DIP switches on the PTZ...
Figure 2-3 2.3.2 DIP Switch Setup Users must set the address number, baud rate and parity parameters of speed dome before controlling it. Only after all these settings are completed, can the speed dome respond to its control commands. Note ...
Figure 2-4 Address …… ………………………………………………………………… Table 2-1 2.3.4 Baud Rate and Parity Setup The functions which need to be set are different for analog speed dome and HDCVI speed dome, which will be introduced respectively. 2.3.4.1 Analog Speed Dome It is used to set speed dome baud rate and parity. 1 and 2 bits are used to set baud rate while 3 and 4 bits are used to set parity, see Figure 2-5.
2.3.4.2 HDCVI Speed Dome It is to set the speed dome baud rate. 1 and 2 bit are used to set baud rate, 3 and 4 bit are used to set HD/SD video mode. See Figure 2-6 for baud rate and mode; refer to Table 2-4 and Table 2-5 for baud rate and mode setup.
Figure 2-9 2.5 Reset Button Location and SD Card Installation You can see there is a RESET button and Micro-SD card slot on the PTZ mainboard after you open the cover. See Figure 2-10. Reset button is used to reset network system. Micro-SD card is used for data storage.
The speed dome has various brackets suitable for different environments. For detailed information, please refer to chapter 3 to chapter 8. Here we are going to install the analog speed dome with the example of analog speed dome wall-mounted bracket. 2.6.1 Install Quick Mounting Connector Please twine Teflon tape around the screw thread of the quick mounting connector and turn it into the screw thread of the wall-mounted bracket.
Figure 2-12 2.7.2 Speed Dome Cable 2.7.2.1 Cable Description The camera is equipped with a multi-functional combination cable by default, which includes power cable, video cable, audio cable, RS485 control cable, alarm cable, network cable, high- frequency cable and optical fiber cable etc. The cable detail is shown in Figure 2-13. Figure 2-13 Note Different models have different cable combinations;...
Page 20
Figure 2-14 2.7.2.2 Cable Connection Buckle the safety hook of speed dome on the quick mount connector; connect the integrated cable reserved by wall-mounted bracket to the corresponding power cable, video cable, audio cable, RS485 control cable, alarm cable, network cable, high-frequency cable and optical fiber cable etc.
Figure 2-15 2.7.2.3 Alarm Cable Connection The alarm cable connection mode and config steps are shown as follows: Step 1 Connect alarm input device to the ALARM_IN and ALARM_GND of the user cable. Step 2 Connect alarm output device to the ALARM_OUT and ALARM_COM of the user cable, alarm output is the relay switch output.
Page 22
Line up the straight edge of the flange of the IR speed dome to the straight edge of the quick installation port, and then push the speed dome to the bottom of the port slowly. Step 3 Use your hands to turn the M6*14 stainless screw (with spring washer) to the Ф6.5 hole of the straight edge of the IR speed dome.
3 Wall-mounted Bracket Installation 3.1 Mounting Component and Dimension The wall-mounted bracket is shown in Figure 3-1, the dimension is shown in Figure 3-2, the dimension of adapter block is shown in Figure 3-3. Figure 3-1 Figure 3-2...
Figure 3-3 3.2 Installation Steps of Wall-mounted Bracket 3.2.1 Installation Conditions Wall-mounted speed dome can be installed on hard wall structure in both indoor and outdoor environments. The wall needs to meet the following installation conditions: The wall shall be thick enough to install expansion bolts. ...
Page 26
Step 2 Install the intelligent speed dome on the wall-mounted bracket, which is shown in Figure 3-5. Refer to “2.7 Speed Dome Installation” for the installation mode of speed dome. Figure 3-5...
4 Hang-mounted Bracket Installation 4.1 Mounting Component and Dimension The hang-mounted bracket is shown in Figure 4-1, the dimension is shown in Figure 4-2. Figure 4-1 Figure 4-2 Note The adjustment range of bracket length is 200mm by default, 400mm optional. It only needs to replace the connection pole.
4.2 Hang-mounted Bracket Installation Steps 4.2.1 Installation Conditions Hang-mounted speed dome can be installed on hard wall structure in both indoor and outdoor environments. The wall needs to meet the following installation conditions: The wall shall be thick enough to install expansion bolts. ...
Page 29
Figure 4-4 Note It needs to twine enough Teflon tape on the thread of upper part of connection pole and then twist the connection pole firmly to the connection plate. Step 3 Install the speed dome, which is shown in Figure 4-5. Please refer to “2.7 Speed Dome Installation”...
5 Corner-mounted Bracket Installation 5.1 Mounting Component and Dimension The corner-mounted bracket is shown in Figure 5-1, the dimension is shown in Figure 5-2. Figure 5-1 Figure 5-2...
5.2 Corner-mounted Bracket Installation Steps 5.2.1 Installation Conditions Corner-mounted speed dome can be installed on hard wall structure which forms an included angle of 90° in both indoor and outdoor environments. The wall needs to meet the following installation conditions: ...
6 Pole-Mounted Bracket Installation 6.1 Mounting Component and Dimension The pole-mounted bracket is shown in Figure 6-1, the dimension is shown in Figure 6-2. Figure 6-1 Figure 6-2...
6.2 Pole-mounted Bracket Installation Steps 6.2.1 Installation Conditions Pole-mounted speed dome can be installed on hard pole-shaped structure in both indoor and outdoor environments. The wall needs to meet the following installation conditions: The diameter of the pole structure shall comply with the installation dimension of the clamp. Default factory hoop is 5 inches for the pole of φ80-130mm.
Page 36
Note Please check if the hoop is firmly fastened after installation, it may result in hoop breakage if it is not properly installed. Step 2 Install speed dome, it is shown in Figure 6-4; please refer to “2.7 Speed Dome Installation” for exact installation mode.
7 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION 7.1 Outdoors This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 6000V, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
7.2 Indoors The yellow and green GND wire or GND screw of the speed dome should be reliably connected by several strands of copper wire with no less than 25mm²and indoor equipotential GND terminal. Please refer to Figure 7-2 for lightningproof installation mode. Figure 7-2...
8 APPENDIX Ⅱ ABOUT RS485 BUS 8.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 8.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
Figure 8-2 8.4 RS485 Bus FAQ Phenomenon Possible Reasons Solution Modify host or speed dome setup ; Speed dome Host address(baud rate) and can run self- speed dome address(baud rate) Switch RS485 positive end and diagnosis but I are not match;...
9 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN AC 24V CABLE DIAMETER AND TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the AC 24V power consumption is below 10%. For the AC device, the max permission voltage power consumption is 10%.
10 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN DC 12V CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the 12V DC power consumption is below 10%. For the DC device, the max permission voltage power consumption is 10%.
11 APPENDIX Ⅴ THE RELATIONSHIP BETWEEN DC 24V CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the DC 24V power consumption is below 10%. For the DC device, the max permission voltage power consumption is 10%.
12 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN DC 36V CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the DC 36V power consumption is below 10%. For the DC device, the max permission voltage power consumption is 10%.
Page 45
13 APPENDIX Ⅳ THE RELATIONSHIP BETWEEN DC 48V CABLE DIAMETER AND THE TRANSMISSION DISTANCE It is the recommended transmission distance when the cable diameter is fixed and the DC 48V power consumption is below 10%. For the DC device, the max permission voltage power consumption is 10%.
Page 47
Note This manual is for reference only. Slight difference may be found in the user interface. All the designs and software here are subject to change without prior written notice. All trademarks and registered trademarks are the properties of their respective owners. ...
Need help?
Do you have a question about the SD6AE series and is the answer not in the manual?
Questions and answers