CONFIGURATION
CONFIGURATION
CONFIGURE BYTE 0
Byte 0
Mask
CONFIGURE BYTE 1
Byte 1
Mask
CONFIGURE BYTE 2
Byte 2
Mask
CONFIGURE BYTE 3
Byte 3
Mask
CONFIGURE BYTE 4
Byte 4
Mask
CONFIGURE BYTE 5
Byte 5
Mask
SETTINGS
SETTINGS
POSITIONING LOOP MONITORING
Dead band timeout
Determinated stroke time up
Determinated stroke time down
Set Position timeout time
FRICTION ALARM DETECTION
KP UP
Limit low (KP Up)
Limit high (KP Up)
Set KP UP Limits
KP Up
KP Up (Ref)
Set KP Up (Ref)
KP DOWN
Limit low (KP Dn)
Limit high (KP Dn)
Set KP Down Limits
KP Down
KP Down (Ref)
Set KP Down (Ref)
Y OFFSET UP
Limit low (Offset Up)
Limit high (Offset Up)
Set Offset Up Limits
Y Offset Up
Y Offset Up (Ref)
Set Y Offset Up (Ref)
Y OFFSET DOWN
Limit low (Offset Dn)
Limit high (Offset Dn)
Set Offset Down Limits
Y Offset Down
Y Offset Down (Ref)
Set Y Offset Down (Ref)
STICTION ALARM DETECTION
TV UP
Limit low (Tv Up)
Limit high (Tv Up)
Set TV Up Limits
TV Up
TV Up (Ref)
Set TV Up (Ref)
TV DOWN
Limit low (Tv Dn)
Limit high (Tv Dn)
Set TV Down Limits
TV Down
TV Down (Ref)
Set TV Down (Ref)
ZERO POINT DISPLACMENT
Zero Point Deviation Value
Set Zero Point Deviation
GENERAL SETTINGS
Time latch
Set Time Latch
34 OI/DHH805-EN Rev. D | Handheld communicator Model DHH805-A
NE107 CONFIGURATION
SENSOR
Position measurement Failure
Edit
OPERATION
OPERATION 1
Setpoint out of range
Edit
Controller inactive
Edit
Electronic temperature out of limits
Edit
Overpressure from supply
Edit
Supply pressure limit low exceeded
Edit
Supply pressure limit high exceeded
Edit
Pressure NV chip defect
Edit
OPERATION 2
Pressure hammer from supply
Edit
Analog output simulation active
Edit
Binary output simulation active
Edit
Fail safe active - via user
Edit
Binary input active
Edit
Analog output supply fault
Edit
ACTUATOR
ACTUATOR GROUP 1
Valve blocked
Edit
Positioning timeout - Check valve maintenance
Edit
kp up exceeded
Edit
kp Down exceeded
Edit
Stroke counter limit exceeded
Edit
Travel counter limit exceeded
Edit
Leakage during operation
Edit
Leakage chamber 1
Edit
Leakage chamber 2
Edit
Leakage in actuator
Edit
ACTUATOR GROUP 2
Pressure NV Data defect
Edit
tv up exceeded
Edit
tv down exceeded
Edit
Y-Offset Up exceeded
Edit
Y-Offset Down exceeded
Edit
Friction limit exceeded
Edit
Stiction limit exceeded
Edit
Universal input out of range
Edit
Partial stroke failed
Edit
Universal input limit exceeded
Edit
7 HART
Communication
®