Table E: INSTALLER/SERVICE MENU — POWER DEFROST Configuration
Item
Set Current
Time
Pump Periods
Pump On Time 1
Pump Off Time 1
Pump Speed 1
Return Valve 1
Suction Valve 1
Pump On Time 2
Pump Off Time 2
Pump Speed 2
Return Valve 2
Suction Valve 2
Pump On Time 3
Default
Range
Value
12:00A–11:59P
0–4
12:00A–11:59P
12:00A–11:59P
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Pool/Spa
Pool/Spa
12:00A–11:59P
12:00A–11:59P
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Pool/Spa
Pool/Spa
12:00A–11:59P
21
Access Level
---
Installer
Installer
---
Installer
---
Installer
Installer
Pool
Installer
Pool
Installer
---
Installer
---
Installer
Installer
Pool
Installer
Pool
Installer
---
Installer
Description
Selects current time – "A" or "P" will
indicate whether the set time is AM
or PM.
Only available if Pump Operation
in the Installer's Menu is set to
"4-Speed Enabled" or "Variable
Enabled".
Select ON time for Pump Period #1 to
take effect.
Select OFF time for Pump Period #1
to stop.
On 4-speed pumps, this denotes the
selected pump output (which connects
to the pump for the selected speed)
for this pump period. On Variable
speed pumps, this denotes the PWM
signal to be provided to the pump for
pump operation.
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Select ON time for Pump Period #2 to
take effect.
Select OFF time for Pump Period #2
to stop.
On 4-speed pumps, this denotes the
selected pump output (which connects
to the pump for the selected speed)
for this pump period. On Variable
speed pumps, this denotes the PWM
signal to be provided to the pump for
pump operation
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Select ON time for Pump Period #3 to
take effect.

Advertisement

Table of Contents