C. CONDENSATION SEEMS EXCESSIVE
Heat pumps can produce a large amount of condensation (water) during operation. If you suspect
that the heat pump is leaking:
a. Use a pool chemistry test kit to confirm there is no chlorine in the condensation. Or,
b. Shut the heat pump OFF and leave the filter pump running to see if the water stops
dripping. If the water stops dripping, the heat pump is not leaking.
XII. Service Call Verification
Before you make a service call, first determine if the problem is:
• Warranty Service
• Heat pump operation (power supply, water flow, or time clock adjustment)
NOTE: The MANUFACTURER IS NOT RESPONSIBLE for these adjustments.
POWER SUPPLY
• Verify that all circuit breakers are reset and working properly.
• If the
lamp on the control panel still does not light, contact the installing dealer,
Power
since it may be a power problem requiring an electrician.
WATER FLOW
• Verify that the pool filter is clean to provide good flow.
• Verify that valves are properly positioned to allow adequate water flow through the heat
pump.
• If the
Water Flow
in the pool, verify that all valves are positioned correctly.
TIME CLOCK ADJUSTMENT
Verify that the time clock is set to permit the unit to run long enough to heat properly.
lamp on the control panel still does not light, and water is circulating
9