Item
Pump Off Time 3
Pump Speed 3
Return Valve 3
Suction Valve 3
Pump On Time 4
Pump Off Time 4
Pump Speed 4
Return Valve 4
Suction Valve 4
Faults Last
Clear Faults
Run Hours
XXXX
Cycles
XXXX
Default
Range
Value
12:00A–11:59P
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Pool/Spa
Pool/Spa
12:00A–11:59P
12:00A–11:59P
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Pool/Spa
Pool/Spa
22
Access Level
---
Installer
Installer
Pool
Installer
Pool
Installer
---
Installer
---
Installer
Installer
Pool
Installer
Pool
Installer
Installer/
Service
Installer/
Service
Installer/
Service
Description
Select OFF time for Pump Period #3
to stop.
On 4-speed pumps, this denotes the
selected pump output (which connects
to the pump for the selected speed)
for this pump period. On Variable
speed pumps, this denotes the PWM
signal to be provided to the pump for
pump operation.
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Select ON time for Pump Period #4 to
take effect.
Select OFF time for Pump Period #4
to stop.
On 4-speed pumps, this denotes the
selected pump output (which connects
to the pump for the selected speed)
for this pump period. On Variable
speed pumps, this denotes the PWM
signal to be provided to the pump for
pump operation.
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Fault history starting with the most
recent and going back to 10 last faults.
Using the UP/DOWN buttons scrolls
through the fault history. If there are
no faults present, the display will read
"All Faults Clear".
Holding down the UP and DOWN
buttons for 3+ seconds clears the
recorded fault history and "Faults
Cleared" appears on the display.
Displays the number of run hours that
the compressor has been running as
well as the number of cycles that the
unit has operated.