Rated Indoor Airflow (cfm)
The table to the right lists the rated indoor airflow used
for the AHRI efficiency rating for the units covered in this
document.
Position:
Example:
Unit/Series/Model
50TCQ - Packaged Rooftop Heat Pump
Refrig. Systems Options
D = Two Stage Cooling Models
Cooling Tons
14 - 12.5 ton
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
G = SA Smoke Detector and CO
H = RA + SA Smoke Detector and CO
J = Condensate Overflow Switch (electro-mechanical controls only)
K = Condensate Overflow Switch and RA Smoke Detectors
L = Condensate Overflow Switch and RA and SA Smoke Detectors
Indoor Fan Options
1 = Standard Static Option – Belt Drive
2 = Medium Static Option – Belt Drive
3 = High Static Option – Belt Drive
C = High Static Option with High Efficiency Motor
Coil Options (Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
Design Revision
– = Factory Design Revision
1
2
3
4
5
6
7
8
5
0
T
C
Q
D
1
4
2
2
2
Fig. 1 - - 50TCQD14 Model Number Nomenclature (Example)
Model Number
50TCQD14
9 10 11 12 13 14 15 16 17 18
A
1
A
6
–
0
B
2
Intake / Exhaust Options
A = None
B = Temperature Economizer with Barometric Relief
F = Enthalpy Economizer with Barometric Relief
K = 2-Position Damper
U = Temperature Ultra Low Leak Economizer with
W = Enthalpy Ultra Low Leak Economizer with
Base Unit Controls
0 = Electro-mechanical Controls can be used with W7212
EconoMi$er
1 = PremierLink™ Controller*
2 = RTU Open Multi-Protocol Controller
6 = Electro-mechanical with W7220 Economizer
controller Controls. Can be used with W7220
EconoMi$er X (with Fault Detection and Diagnostic)
* PremierLink controller can not be used with Staged Air
Volume (SAV™) 2-speed indoor fan motor.
It is recommended with models using Staged Air Volume
(SAV) 2-speed indoor fan motor control that the
EconoMi$er X system be used because it contains
two ventilation set points, one for each fan speed.
4
Full Load Airflow (cfm)
4500
A
0
Factory Assigned
0 = Standard
1 = LTL
3 = CA Seismic Complaint
4 = LTL and CA Seismic Compliant
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
G = 2-Speed Indoor Fan (VFD) Controller
J = 2-Speed Indoor Fan (VFD) Controller
and Non-Fused Disconnect
K = 2-Speed Indoor Fan (VFD) Controller
and Thru-The-Base Connections
M = 2-Speed Indoor Fan (VFD) Controller
with Non-Fused Disconnect and
Thru-The-Base Connections
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
Unpowered Convenience Outlet
5 = Hinged Panels and
Powered Convenience Outlet
Barometric Relief
Barometric Relief
®
IV (Non-Fault Detection and Diagnostic)