Technical Specifications; Technical Specifications Mp6 - Bartels Mikrotechnik mp6 Operating Manual

Micropump and controller
Hide thumbs Also See for mp6:
Table of Contents

Advertisement

3. Technical specifications

3.1 Technical specifications mp6

mp6
Pump type
Number of actuators
Dimensions without connectors
Weight
Fluidic connectors
Electric connector
Power consumption
Self-priming
Pumping media
Operating temperature
Life time
IP code
Materials in contact with media
Suitable evaluation controller
Typical values of flow and back pressure for selected media
(values defined with mp-x: 250 V, SRS):
Gases
Max. back pressure
Liquids
Water
Max. back pressure
1
Typical values. Values can vary under application conditions. Content is subject to changes without notice.
2
recommended tubing: 1.3 mm inner diameter.
3
Conditions: suction pressure < 10 mbar, DI water, settings mp-x: 100 Hz, 250 V, SRS, the max. flow rate will be reached after a few minutes of
operation time.
4
Conditions: DI water, room temperature, settings mp-x: 100 Hz, 250 V, SRS.
5
Can be changed to IP44.
6
The mp6 is not stable against concentrated alcoholic solutions as MeOH or EtOH.
6
1
piezoelectric diaphragm pump
barbed tube clip (outer diameter
1.9 mm, length 3.5 mm)
flex connector / Molex FCC
liquids, gases and mixtures
polyphenylene sulphone (PPSU)
mp-x, mp6-EVA and mp6-OEM
Max. flow
Max. flow
7 ml/min +/- 15% (100 Hz)
600 mbar +/- 15% (100 Hz)
Order code: mp6
2
30 x 15 x 3.8 mm³
2 g
2
1.25 mm pitch
< 200 mW
3
yes
0 – 70°C
4
5000 h
5
IP33
6
18 ml/min (300 Hz)
100 mbar (300 Hz)
Bartels Mikrotechnik GmbH, Otto-Hahn-Str. 15, 44227 Dortmund, Germany
www.micro-components.com, microComponents@bartels-mikrotechnik.de
Tel: +49-231-9742-500, Fax: +49-231-9742-501

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp6-ppMp6-evaMp-xMp6-oem

Table of Contents