4.1.1 Connecting the mp6/mp6-pp to the cable

The mp6/mp6-pp pump can be connected via a standard electrical connector manufactured by Molex. The
layout of the connector and pin assignment of the mp6/mp6-pp is as shown below. Each piezo (P1 / P2) has
a single lead for the negative (-P1/-P2) and the positive (+P1/+P2) supply voltage.
Subject to change without further notice
The recommended connector is a 4 pin 1.25 mm pitch FCC connector manufactured by Molex, part number
39 53 2045. The connector is available in different versions to fit various applications. Reference drawings
and further specifications are available under www.molex.com .
The recommended maximum wire length between controller and the pump is 1 m. The customer has to
assure that the assembly of pump, controller and electrical connection complies with the EMC regulations
and electrical safety in the specific field of application.
To connect the mp6/mp6-pp and Molex, refer to following three figures. Orientate both components as
indicated on the first picture, the mp6/mp6-pp facing downwards with its serial number marking (!) and
the molex connector with the four small openings visible from above. Then insert the mp6/mp6-pp flex into
the Molex connector (Step1). Close the Molex connector to complete the interconnection between both
components (Step 2).
Step 1
Step 2
Step 3
If the pump should be removed again, the Molex connector needs to be opened before removal!
Bartels Mikrotechnik GmbH, Otto-Hahn-Str. 15, 44227 Dortmund, Germany
www.micro-components.com, microComponents@bartels-mikrotechnik.de
Tel: +49-231-9742-500, Fax: +49-231-9742-501
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp6-ppMp6-evaMp-xMp6-oem

Table of Contents