Electrical connections – AH
Bottom part – AH:
10-pole screw terminal
1 ) S1, S3, S4 – Common*
2 ) S2 – Common
3 ) S1 – Actuated
4 ) S2 – Actuated
5 ) S1 – Not actuated
6 ) 0 VDC (anti-tamper, LED 1, LED 2)
7 ) S3 – Actuated
8 ) S4 – Actuated
9 ) Anti-tamper – Common
10 ) Anti-tamper – Operator detected
NB: 10-pole screw terminal with wiring suited for safety relays in the RT-series or Pluto safety-PLC. Intended for
user assembled cable. Anti-tamper PCB is possible.
Electrical connections – AJ
Bottom part – AJ:
16-pole screw terminal
According to top part.
NB: 16-pole screw terminal, wiring suited for any monitor. Intended for user assembled cable. Anti-tamper PCB is
possible.
2TLC172052M0201, rev. A
2011-10-06
1
2
3
Male pins in 2x8
Molex male
10-pole screw
terminal
1
2
3
* NB: COM signal must be +24 VDC for proper LED and anti-tamper PCB
function.
1
2
3
Male pins in 2x8
Molex male
16-pole screw
terminal
10
4
5
6
7
8
9
10
4
5
6
7
8
9
10
4
5
6
7
8
9
10
11
12
13
14
15
16
11
12
13
14
15
16
www.jokabsafety.com