Checking Bandwidth Usage and Adjusting the Packet Interval (RPI)
34
a. Click the Set Packet Interval (RPI) Button at the bottom of the Usage
of Device Bandwidth Dialog Box.
b. The Set Packet Interval (RPI) Dialog Box will be displayed. In the Tar-
get Device Area, deselect the target devices that are not being adjust-
ed by removing the check marks.
c. Input a new packet interval (RPI) value, and click the OK Button.
Method 3: Changing a Particular Connection's Packet Interval (RPI)
Setting
The Usage of Capacity can be adjusted by individually changing the packet
intervals (RPI) setting for a particular connection.
In this case, the Usage of Capacity will also change for the device that is
the target device of the connection which was adjusted.
Section 2-3