    General index 1. FIRST COMMISSIONING PROCEDURE. 2. GENERAL DESCRIPTION OF THE TOUCH PANEL. 2.1. STRUCTURE OF THE TOUCH PANEL. 2.2. TOUCH PANEL SECTIONS. 3. DESCRIPTION OF THE SECTIONS. 3.1. LOG IN. 3.2. START SCREEN «HOME». 3.2.1. Lock. 3.2.2. Help. 3.2.2.1. Quick guide.
  • Page 4: First Commissioning Procedure

    ECO-Mode shifting (loads supplied by the static ˆ bypass line) or load feedback by the UPS inverter. In case the desired figure was not in that table, the nearest figure must be selected. Refer to this section for any of the quoted operating. SALICRU...
  • Page 5: General Description Of The Touch

    2. GENERAL DESCRIPTION OF THE TOUCH PANEL. 28 / 11 / 2016 Log In 22 : 27 : 23 Input Frequency Output Frequency 50.1 Hz 50.0 Hz Out SW: Open Output load Information available in equipments to work in parallel only. Even tough any number can be assigned as 226.5 V 230.0 V...
  • Page 6: Description Of The Sections

    When pressing over this icon , you access the «Bat- 230.0 V tery» menu directly. Parallel Id. 1 230.0 V Battery Temperature When pressing over any of these icons, you access 31.6 °C the «Output» menu directly. Fig. 4. Start screen (Single - Three phase I/O example). SALICRU...
  • Page 7: Help

    When an icon is displayed in red colour, it will mean that an In the top of this section, it is located the «Backward» key: alarm is present. Next it is shown the icon representation and its meaning: The «Backward» key will move to the end-user ...
  • Page 8: Time And Date

    Options: No parity, Even or Odd. Stop bits. ˆ Time & Date Options: 1 and 2 Hour Communication protocol. ˆ Minute Year Options: SEC or MODBUS 2 Month Week Day Fig. 10. Time and date setting of the equipment. SALICRU...
  • Page 9 Port 0 Back Modbus Address Baudrate 9600 Parity None Stop Bits Protocol MODBUS Measures Alarms Status - Control Rated Values Plots Advanced Fig. 11. Port 0 parameters. The «Drop-down» button allows, depending on the field, opening the menu and selecting one of the pro- posed variables or entering a value by means of the pop up keyboard, to change it.
  • Page 10: Main Menu

    UPS output can be displayed: Bypass Failure: Not Synchronised Inverter Voltage. ˆ Frequency. ˆ Current. ˆ Power factor. ˆ Apparent power. ˆ Page / Active power. ˆ Measures Alarms Status & Control Status - Control Plots Advanced Fig. 13. Active alarms screen. SALICRU...
  • Page 11 Any alarm shown in the «Active alarms» submenu of the touc Representation on the touch screen Alarms Ref. screen, triggers an acoustic alarm with the same modulation and Some Unit(s) Blocked intensity for any of them. due to Maintenance 4.12 Bypass The side menu has four graphic buttons, which are described as CAN BUS 1...
  • Page 12 Inverter Block Historic side menu in «Alarms» section, the last one hundred Inverter Blocked: alarms in the equipment can be consulted through BLK. UPS>> 4.60 BLK. INV the screen labelled as «Data Logger» (see Fig. 14 as an example). SALICRU...
  • Page 13: Battery Test Features

    Data Logger When touching over any touch «Start/Stop» graphic, a dialogue “Pop up” window will be displayed, by asking the end user if Flag Back Alarm Description Date Inverter Parallel Code the selection is the correct one (see Fig. 15). Mains Failure 27/11/16 - 00:50:17 READY...
  • Page 14 Input Voltage Phase R 5 A/ div Input Current creasing the scale unit/frame of the red colour graph, in order to decrease as regards to the screen. The touch button «Zoom + red» allows the end-user de- Fig. 17. Recorder screen. SALICRU...
  • Page 15 In the side menu there are several touch buttons related with To access, it is needed a «Password», which must be entered the data logger with the following functionality. Notice that the by means of the pop up keyboard displayed when pressing the «Setting»...
  • Page 16 Avda. de la Serra 100 08460 Palautordera BARCELONA Tel. +34 93 848 24 00 Fax +34 93 848 22 05 services@salicru.com SALICRU.COM The Technical Service and Support (T.S.S.) network, Com- mercial network and warranty information are available in website: www.salicru.com...