Troubleshooting Guide Related To Rf - Verizon Smart-Cell User Manual

33 dbm
Table of Contents

Advertisement

4.4.3. Troubleshooting Guide Related to RF

Item
System input power
Check before
system
operation
Check points before
Check after
Check points after open
system
operation
When
repeater
Check electricity cord
does not
connection status
work
properly
Check Point
range
System gain
(DL/UL)
Output power
at server port
open for service
for service
Troubleshooting
-Downlink: -100dBm ~ -27dBm
-Uplink: -100dBm ~ -27dBm
- 60dB ~ 90dB
- Downlink: 33dBm ± 2dB
- Uplink: 33dBm ± 2dB
-Please check quantity of all accessories with
specification before you set up
-Fit
cable
length
condition
Check following status;
-Verify that the antennas are securely mounted
and pointed in the correct directions
-Connection status between antennas and RF
cable
-Verify that the Repeater is securely mounted
-Proper AC power status
-Grounding status of electrical circuit
-Coaxial cable (RF) construction status
-Connectors and combiners connection status
-Cable connection status against leakage of
water
-Re-plug in Adapter cord