Field
Filter service has not
Replaceable
matches between
module
Amp Unit and DFM
failure
When mount
Tamper
information (in the
Detected
system ) is changed
If the communication
between the NMS
Communicat
Board and Amp Unit
ion Failure
would not operating
normally
Power
The internal Power
Supply
out
Supply detects
of range
improper Voltage
Internal AMP
Over
temperature exceeds
Temperature
the Temperature
Limit
When the unit has
Reset alarm
reset
When the operates
Manual
shutdown algorithm,
Shutdown
after re-check
in the event of a fan
FAN
failure
* Close the repeater door if opened and verify that
the closest indoor coverage antenna is not in the
same room as the repeater.
* Call to GST's Tech Support Team to verify that all
the settings are correct.
* After 5 minutes clear automatically.
* If you want to disable, you can on the Alarm
Configuration page.
* SNMP board or AMP unit need to reset.
* Open the rear cover and check the each cable.
* If the system is working fine, disable the alarm on
the Alarm Configuration page.
* Call to GST's Tech Support Team to verify that all
the settings are correct.
* Verify that the Temperature Limit is set between
176 °F ~ 201 °F on the RF Configuration page.
(Default Value is 163°F)
* After 30 seconds clear automatically.
* By using a switch on the back of the repeater,
resets the power
* Reset the AMP unit, By Web UI.
* Replace the fan
26
Verizon User Manual
Smart-Cell Repeater