Verizon Smart-Cell User Manual page 24

33 dbm
Table of Contents

Advertisement

Downlink
Downlink path gain is
Hardware
6dB less than RSSI
failure
plus Output Power
Downlink
Input RSSI from
Donor
Donor site is 8dB less
power
too
than Downlink Low
low
Input Limit
When the VSWR
Downlink
Ratio on the Server
VSWR
Port is greater than
3 : 1
Downlink
Downlink Input
Donor
Power exceeds -
power
too
25dBm
high
Downlink
Synthesizer (in
Synthesizer
Downlink path) has
failure
occur Failure
Downlink
If an external signal is
Interfere
higher than the in
power
band signal, more
exceeded
than 15dB signal
Uplink
Out
Uplink Output Power
of
band
exceeds Uplink Upper
emissions
Limit
out of spec
* By default, if the Downlink Low Output Variance is
set to 10dB, the Repeater will not report this alarm.
* Increase the Downlink Low Output Variance on the
RF Configuration Page.
* By default, if the RSSI Lower Limit is set to -93dBm,
the Repeater will not report this alarm.
* Decrease the Downlink Low RSSI Limit level on the
RF Configuration Page.
* Increase the RSSI level into the Repeater.
* "Sweep the line" to check for loose or damaged
connectors and/or cabling.
* If after checking the entire Server side, the VSWR
alarm still exists and the system is working fine,
Disable the alarm on the Alarm Configuration page.
* Check the direction of donor antenna
* Even if higher input power after the modifying
direction of donor antenna, Be adding an attenuator
at the Donor port.
* By using a switch on the back of the repeater,
resets the power
* Call to GST's Tech Support Team and exchange the
AMP unit.
* Call the GST's Tech Team, resolved in accordance
with the procedure.
* The Uplink Output Power should not exceed the
maximum composite power spec for this unit.
* If the Uplink Output Power is not exceeding the
composite power spec for this unit, try to increase
24