Verizon Smart-Cell User Manual page 25

33 dbm
Table of Contents

Advertisement

Uplink
Power
at
Uplink Input Power is
coverage
higher than -25dBm
port
too
high
Uplink
Synthesizer
Synthesizer (in uplink
failure
path) has occur
(Uplink
Failure
Hardware
failure)
Uplink
When an alarm
(Downlink)
occurs in DFM's at
Software
the AMP unit.
failure
Insufficient isolation
Oscillation
is detected when the
detected/Lo
Repeater is at
w isolation
minimum gain
the Uplink Upper Limit on the RF Configuration Page.
* Add equal amounts of Uplink and Downlink
attenuation until the Uplink Output Power is less
than the Uplink Upper Limit.
* Set the ALC Uplink Limit on the RF Configuration
Page to a value lower than the Uplink Upper Limit
* Check the direction of Coverage antenna
* When another device is connected to the Coverage
port as DAS System
1) Add an attenuator on Coverage port, or
2) Uplink to adjust the output of the additional
equipment.
* By using a switch on the back of the repeater,
resets the power
* Call to GST's Tech Support Team and exchange the
AMP unit.
* By using a switch on the back of the repeater,
resets the power
* Call to GST's Tech Support Team and exchange the
AMP unit.
* Verify that the Donor antenna is on the same side
of the building as the Donor site, and if needed, raise
the Donor antenna up on a pole.
* Change the types of antennas used, such as Yagi to
Corner-Reflector for outdoors, and Omni to a Panel
for indoor use.
* Move the closest indoor service antenna farther
away from the outside Donor antenna.