To disable all SNMP traps, issue a Server SNMP Trap command with the
Disable and All parameters. In this case, the numbered list is not displayed.
SERVER SNMP TRAP DISABLE ALL
For more information, see Server SNMP Trap command in Chapter 5. The
Equinox web site www.equinox.com/support describes the supported traps.
To add or delete SNMP trap destination addresses:
1.
To add an SNMP trap destination address, issue a Server SNMP Trap
Destination command with the Add parameter and the destination's
IP address. You may defi ne up to four destination addresses, using
separate commands.
SERVER SNMP TRAP DESTINATION ADD <ip_address>
2.
To delete an SNMP trap destination address, issue a Server SNMP Trap
Destination command with the Delete parameter and the destination's
IP address.
SERVER SNMP TRAP DESTINATION DELETE <ip_address>
For more information, see Server SNMP Trap Destination command in Chapter 5.
To add, copy or delete port alert strings:
1.
To add a port alert string, issue a Port Alert Add command, specifying the
port number and a 3-32 character string. You may defi ne up to ten strings
for each port, using separate commands. The alert string will only generate
a trap if the portAlert trap is enabled with a Server SNMP Trap command.
PORT <port> ALERT ADD "<string>"
2.
To delete a port alert string, issue a Port Alert Delete command, specifying
a port number.
PORT <port> ALERT DELETE
The CCM displays a numbered list of alert strings that have been defi ned
for the specifi ed port with a prompt requesting you to select alert string(s)
to delete. Indicate the alert strings to be deleted by entering an alert
string's list number, several numbers separated by commas, a range of
numbers separated by a dash or a combination of numbers with commas
and dashes. To delete all alert strings, type ALL. To cancel the command,
press Enter.
3.
To copy the defi ned alert strings from one port to another port, issue a Port
Alert Copy command, specifying the port numbers to be copied to and from.
PORT <to_port> ALERT COPY <from_port>