- ELECTRICAL STARTING SYSTEM
0
AND RECHARGE ALTERNATOR
If different values are registered, make the
checks described below and, if a satisfactory
result is not obtained, the alternator must be
replaced.
32 Remove the starting system
33 Remount the tank
[u
34 Remove the conveyor (32).
35 Loosen the two screws (33) securing the alter-
nator coil (34), release the brake manually and
rotate the flywheel (35) until the magnetic
inserts are lined up with the poles of the coil
core (34).
36 Insert a 0.35 mm thickness gauge (36) between
the magnet flywheel (35) and the coil poles.
Push the coil until the poles come in contact
with the thickness gauge and secure both
screws (33). Tighten the screws remembering
that the air gap must be between 0.25 and 0.40
mm.
37 Remount the conveyor (31).
38 Remount the tank
[u
39 Remount the starting system
Tightening torques
4
Motor fixing screws ............................ 8-10 Nm
Technical information
Recharge values ........................... 0,45-0,55 Amps
Special equipment
-
Universal tester
-

Ammeter clamp

© by GLOBAL GARDEN PRODUCTS
SERVICE MANUAL