Electrical Starting System And Recharge - GGP SV200 Workshop Manual

Table of Contents

Advertisement

<= ...BACK... <=
6.11.
- ELECTRICAL STARTING SYSTEM
0
AND RECHARGE ALTERNATOR
6.11 ELECTRICAL STARTING SYSTEM
AND RECHARGE ALTERNATOR
GENERAL INFORMATION
The electrical starting system consists of a motor
powered by a 12 Volt battery (fitted to the machine).
Battery recharging is assured by a coil alternator
that receives impulses from the engineís magnet fly-
wheel.
SERVICING PROCEDURES
A) Removing the starter motor
1
Remove the magnet flywheel
2
Disconnect the connector (1) from the machi-
ne's cabling.
3
Disconnect the power cable (2) and earth cable
(3).
4
Unscrew the two screws (4) and remove the
starter motor (5).
5
Reverse the above operations to reassemble;
bear in mind the function of the three cables
when reconnecting the connector (1):
blue = recharge
red = starter motor power supply
black = earth
6
Remove the flywheel
B) Removing and cleaning
the starter motor pinion
11 Remove the starter motor
12 With the help of a screwdriver turn the pinion
(11) and check that it can slide axially until it
compresses the spring (12).
13 Should deposits and dirt prevent complete
return proceed as follows:
© by GLOBAL GARDEN PRODUCTS
SERVICE MANUAL
[u
6.9.E].
[u 6.9.E]
[u
6.11.A].
1
4
3
12
11
SV200 R200
2007
••••
from
to
1 / 4
page
5
4
2
4/2007