1

Program the Travel

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY
INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door must reverse on contact with
1-1/2" (3.8 cm) high object (or 2x4 laid fl at) on fl oor.
While programming, the UP and DOWN buttons can be used to move the door as needed.
1.1
Press and hold the
Adjustment Button until the
UP Button begins to fl ash
and/or a beep is heard.
1.3
Once the door is in the
desired UP position press
and release the Adjustment
Button. The garage door
opener lights will fl ash twice
and the DOWN Button will
begin to fl ash.
1.5
Once the door is in the
desired DOWN position
press and release the
Adjustment Button. The
garage door opener lights
will fl ash twice and the UP
Button will begin to fl ash.
1.7
Press and release the DOWN Button. The door
will travel to the programmed DOWN position.
Programming is complete.
14
1.2
Press and hold the UP Button until the door is in
the desired UP position.
1.4
Press and hold the DOWN Button until the door is
in the desired DOWN position.
1.6
Press and release the UP Button. When the door
travels to the programmed UP position, the
DOWN Button will begin to fl ash.
If the garage door opener lights are fl ashing 5 times during
the steps for Program the Travel, the programming has
timed out. If the cable tension monitor is not installed or
is sensing too much slack in the cable, the garage door
opener light will fl ash 5 times. Ensure the cable tension
monitor is correctly installed then follow the steps for
Program the Travel. If the garage door opener lights are
fl ashing 10 times during the steps for Program the Travel,
the safety reversing sensors are misaligned or obstructed
(refer to page 12). When the sensors are aligned and
unobstructed, cycle the door through a complete up and
down cycle using the remote control or the UP and DOWN
buttons. Programming is complete. If you are unable
to operate the door up and down, repeat the steps for
Programming the Travel.