HP ProLiant XL730f Gen9 User And Maintenance Manual page 28

Hide thumbs Also See for ProLiant XL730f Gen9:
Table of Contents

Advertisement

To use the utility to upgrade the firmware:
Download the FWUPDATE flash component from the HP website (http://www.hp.com/go/hpsc).
1.
Save the FWUPDATE flash components to a USB key.
2.
Set the boot order so the USB key will boot first using one of the following options:
3.
Configure the boot order so the USB key is the first bootable device.
o
Press F11 (Boot Menu) when prompted during system boot to access the One-Time Boot Menu. This
o
menu allows you to select the boot device for a specific boot and does not modify the boot order
configuration settings.
Insert the USB key into an available USB port.
4.
Boot the system.
5.
The FWUPDATE utility checks the system and provides a choice (if more than one exists) of available
firmware revisions.
To download the flash components, see the HP website (http://www.hp.com/go/hpsc).
For more information about the One-Time Boot Menu, see the HP UEFI System Utilities User Guide for HP
ProLiant Gen9 Servers on the HP website (http://www.hp.com/go/ProLiantUEFI/docs).
FWUpdate command from within the Embedded UEFI Shell
For systems configured in either boot mode, update the firmware:
Access the System ROM Flash Binary component for your server from the HP Support Center
1.
(http://www.hp.com/go/hpsc). When searching for the component, always select Cross operating
system to locate the binary file.
Copy the binary file to a USB media or iLO virtual media.
2.
Attach the media to the server.
3.
Boot to Embedded Shell.
4.
To obtain the assigned file system volume for the USB key, enter Map –r . For more information about
5.
accessing a file system from the shell, see the HP UEFI Shell User Guide for HP ProLiant Gen9 Servers
on the HP website (http://www.hp.com/go/ProLiantUEFI/docs).
Change to the file system that contains the System ROM Flash Binary component for your server. Enter
6.
one of the fsx file systems available, such as fs0 or fs1, and press Enter.
Use the cd command to change from the current directory to the directory that contains the binary file.
7.
Enter fwupdate –d BIOS -f <filename> to flash the system ROM.
8.
For help on the FWUPDATE command, enter the command:
help fwupdate -b
Reboot the server. A reboot is required after the firmware update for the updates to take effect and for
9.
hardware stability to be maintained.
For more information about the commands used in this procedure, see the HP UEFI Shell User Guide for HP
ProLiant Gen9 Servers on the HP website (http://www.hp.com/go/ProLiantUEFI/docs).