PARAMETER
Vcc
I
S
Vol
Voh
I
ol
I
oh
t
l-h
1
r
t
h-l
f
Measured with R
=2.4KΩ and C
1
l
PARAMETER
T (op)
T (stg)
Vcc
R
l
I
out
These limits cannot be exceeded without possible damage.
1
P E R F O R M A N C E D ATA
METER
MAXIMUM FLOW
SIZE (in)
RATE (gpm)
⁄
5
8
⁄
3
4
1
1
⁄
1
2
2
For the High Resolution Output of TRICON/E2 transmitters, multiply these values by 36, and for the TRICON/E3, multiply by 40.
1
TRICON/E/E2/E3 TRANSMITTER INSTALLATION AND MAINTENANCE GUIDE
Table 3.3 HF and UP/DN Models (over 0-70°C operating temperature )
DESCRIPTION
Power Supply Voltage
Power Supply Current
Low Digital Pulse Output Voltage
High Digital Pulse Output Voltage
Current @ Vol
Current @ Voh
Output Rise Time
Output Fall Time
=50pF.
l
Table 3.4 All Models Absolute Limits
DESCRIPTION
Operating Temperature
Storage Temperature
Power Supply Voltage
Output Load (pulse output)
Output Current (pulse output)
Table 3.5 T-10 Disc Meters
MAXIMUM
CONTINUOUS
FLOW RATE (gpm)
20
10
30
15
50
25
100
50
160
80
MINIMUM
TYPICAL
11.5
—
20
—
0
—
—
24
-1.0
—
—
0.04
—
—
—
—
1
MINIMUM
MAXIMUM
0
-40
-30
1200
—
NUMBER OF
MINIMUM FLOW
PULSES PER
RATE (gpm)
GALLON
1
⁄
578.10
1
4
⁄
322.60
1
2
⁄
150.80
3
4
1
⁄
67.57
1
2
2
37.30
MAXIMUM
UNITS
26.5
V
50
mA
—
V
26.5
V
—
A
+1.0 W/Voh
A
2
uS
2
uS
UNITS
85
°C
85
°C
30
V
—
KΩ
10
mA
PULSE OUTPUT
FLOW RANGE
@ MAXIMUM
OF 4-20MA
FLOW RATE (Hz)
OUTPUT (gpm)
1
192.70
0–20
161.30
0–30
125.67
0–50
112.62
0–100
100.00
0–160
3-2