For the High Resolution Output of TRICON/E2 transmitters, multiply these values by 36, and for the TRICON/E3, multiply by 40.
1
T-8 disc meters are no longer manufactured. Therefore, all TRICON/E transmitters manufactured for disc meters are the T-10 type. In most cases, the newer
2
T-10 meter chamber is smaller than its corresponding T-8 meter chamber, which results in the TRICON/E having a theoretical "Flow Rate at 20mA Output" that
is greater than the Maximum Flow Rate allowed for the meter. This means that the T-10 type TRICON/E running on a T-8 meter will never actually reach the 20mA
output level during normal operation. The calculated flow rate required to produce a 20mA output is provided as a reference for use in calibrating the 4-20mA
receiving instrument.
METER SIZE
(in)
2
3
4
6
8 (through S/N 31918014)
8 (from S/N 31918274)
10 (through S/N 31919282)
10 (from S/N 31919300)
For the High Resolution Output of the TRICON/E2 transmitters, multiply these values by 9 and for the TRICON/E3, multiply these values by 10.
1
MAXIMUM
METER SIZE
CONTINUOUS
(in)
FLOW RATE (gpm)
1
⁄
1
2
2
3
4
1,200
6
2,500
8
4,000
10
6,500
12
8,000
16
13,500
20
22,000
For the High Resolution Output of the TRICON/E2 transmitters, multiply these values by 9 and for the TRICON/E3, multiply these values by 10.
1