CS-SA18CKP / CU-SA18CKP5

7 Operation Details

7.1.
Cooling Mode Operation
• • • • When selecting the Cooling Mode Operation, the unit will operate according to the setting by the Remote Control and the
operation is as the following.
Time Delay Safety Control
• • • • 3 min. ---- The compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle.
• • • • (Protection of compressor).
7-minutes Time Save Control
• • • • 7 min. ---- The unit will automatically operate in 7 minutes even if the room temperature is not reached.
(Prevention of raising the humidity)
Anti-freezing Control
• • • • If temperature of evaporator is lower than 2°C continuously
for 4 minutes, the compressor will cease to prevent the
evaporator from freezing. Fan speed setting will not be
changed.
• • • • When
temperature
compressor will restart.
During Cooling Mode Operation, the Time Delay Safety Control
is available.
of
evaporator
reaches
10°C,