8.3.
Installation of indoor, outdoor unit
8.3.1.
Select best location
8.3.1.1.

Indoor unit

• • • • There should not be any heat source of steam near the unit.
• • • • There should not be any obstacles to prevent the air
circulation.
• • • • A place where air circulation will be good.
• • • • A place where drainage can be easily obtained.
• • • • A place where noise prevention is taken into consideration.
• • • • Do not install the unit near the doorway.
• • • • Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
• • • • From the floor, the height should be more than eye-level.
8.3.1.2.

Outdoor unit

• • • • If an awning is built over the unit to prevent direct sunlight
or rain exposure, be careful that heat radiation from the
condenser is not restricted.
• • • • There should not be any animals or plants which could be
affected by hot air discharged.
• • • • Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
8.3.1.3.

Piping length and elevation

Piping size
Rated piping Max piping
Gas
Liquid
length
(m)
1/2"
1/4"
7
25
CS-SA18CKP / CU-SA18CKP5
Max
Additional
length
elevation
refrigerant
(m)
(m)
(g/m)
15
10
20