Associating Host Groups To Logical Volumes - HP StorageWorks XP128 User Manual

Lun configuration and security manager xp
Hide thumbs Also See for StorageWorks XP128:
Table of Contents

Advertisement

Figure 18
Add New iSCSI Name dialog box (when registering a host that has previously been connected
to the disk array)
7.
Skip to
step
step 8
through
8.
Right-click the host group and select Add New WWN (Fibre Channel) or Add New iSCSI Name (iSCSI
environment). The Add New WWN (or Add New iSCSI Name) dialog box appears
Fibre Channel and
9.
Select the desired host bus adapter from the WWN/iSCSI name list. If the host bus adapter is not in
the list, enter the WWN (iSCSI name) in the box.
10.If necessary, enter a nickname for the host bus adapter.
11.Click OK. The new WWN (iSCSI Name) and nickname appear below the selected host group in the LU
Path tree.
12.Click Apply in the LUN Manager main pane. A confirmation message appears.
13.Click OK. The settings are applied to the disk array.
NOTE:
For Fibre Channel environments only: If the WWN table (located in the lower-left corner of the
pane) includes a host that you want to register, you can register the host by selecting the host group in the
LU Path tree, selecting the host from the WWN table, and then clicking Add WWN.

Associating host groups to logical volumes

You can use LUN Manager to define LU paths by associating host groups to logical volumes. For example,
if you associate a group of three hosts with logical volumes, LU paths are defined between the three hosts
and the logical volumes.
1.
In the LU Path tree on the LUN Manager main pane, select a host group.
NOTE:
2.
In the CU list above the LDEV table, select a CU number. The LDEV table shows LDEVs in the CU.
3.
In the LDEV table, select one or more LDEVs. Press the Ctrl key to select multiple LDEVs.
4.
In the LU Path table, select the LUs.
5.
Click Add LU Path. A dialog box prompts you to confirm the LU Paths to be defined.
6.
Click OK. The settings are shown in blue in the LU Path table.
7.
Click Apply in the LUN Manager main pane. A confirmation message appears.
8.
Click OK. The settings are applied to the disk array.
Changing or viewing LU path settings
Deleting LU paths
1.
In the LU Path tree on the LUN Manager main pane, select a port.
36
LUN Manager for the XP128/XP1024
11. If the desired host has never been connected via a cable to any port in the array, only
step 10
apply.
Figure 16
for iSCSI).
If you are configuring a NAS environment, you must select the User host group.
(Figure 15
for

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp1024

Table of Contents