Volume Management For The Xp128/Xp1024 - HP StorageWorks XP128 User Manual

Lun configuration and security manager xp
Hide thumbs Also See for StorageWorks XP128:
Table of Contents

Advertisement

2

Volume Management for the XP128/XP1024

Use Volume Management to perform the following tasks:
• "Volume Management (LU Size
• "Volume Size Configuration
Volume Management (LU Size Expansion)
Volume Management (LU Size Expansion or LUSE) combines two or more LDEVs to function as a larger
LDEV. As a result, a host can access a greater amount of storage with a smaller number of LDEVs.
Figure 28
shows the effect of a LUSE configuration.
Figure 28
LUSE configuration
LUSE can combine up to 36 LDEVs into a LUSE volume. The LDEV number of the LUSE volume is the first or
lowest number of the LDEVs making up the LUSE volume. This is the top LDEV, and is the number the host
will recognize.
Drawbacks
Some operating systems may experience slow disk access times with large logical units, if they contain
a large number of high-use files.
The size of a LUSE volume can increase the amount of time required to perform backups.
LUSE rules
Open volume emulation types OPEN-3, OPEN-8, OPEN-9, OPEN-E, OPEN-L, or OPEN-V are
supported.
The maximum number of LDEVs that can be used to create a LUSE is 36.
LDEVs must be of the same emulation type.
LDEVs must be at the same RAID level. Combining RAID 1 and RAID 5 volumes into the same LUSE
volume is supported, but not recommended.
LDEVs or LUSE volumes to be combined must have no assigned path definitions. These are known as
free (or available) LDEVs. For this reason, Business Copy XP, Continuous Access XP, TrueCopy (TC390),
ShadowImage (SI390), and Continuous Access XP Journal pair volumes cannot be targets of LUSE
operations. For more information, see
LDEVs that are to be combined into LUSE volumes must not be reserved for Auto LUN.
When you combine a LUSE volume with another LUSE volume, the range of LDEVs should not be
overlapped.
Expansion)" on page 57)
(VSC)" on page 58)
"LUSE operations that handle a path-defined
LUN Configuration and Security Manager XP user guide for the XP128/XP1024
LDEV" on page 58.
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp1024

Table of Contents