SCALDING HAZARD. If the water temperature is
over 120°F, household members can suffer serious
or fatal scalding and painful and permanent injury.
• The Consumer Products Safety Commission recommends an initial
setting of 120°F, but advised that a slower response time of infants,
aged, disabled and other persons increases the scalding hazard and
may require lower settings.
• Always check the water temperature before use, including washing,
bathing or showering.
• Temperature limiting valves are available from your plumbing supplier.
A check valve must be installed in the boiler return line to prevent
gravity flow through the heat exchanger. This can cause overheating
and result in serious or fatal scalding.
SCALDING HAZARD.
working properly or if this product is not installed in
accordance with the manual, water temperature can reach excessive
levels that may cause serious or fatal scalding. After installation and any
servicing of the unit, verify that the thermostat is working and firmly
inserted in the thermostat well by following the thermostat testing
instructions in the manual.
Failure to use the correct replacement parts may
make your product unsafe.
In limited circumstances, space heating can be lost
in the home with unit utilizing priority mode. Any
demand for space heating is postponed until the water heater has
reached its set temperature. This delay in supplying the space heating
zones is usually not noticed by the inhabitants of the living spaces.
However, in the event of certain malfunctions such as circulator or
thermostat failure, space heating could be delayed indefinitely. If
undetected and uncorrected, freezing damage to piping could result.
If a steel hydropneumatic tank is in place, replace it
with a properly sized diaphragm expansion tank.
Otherwise, significant heat transfer problems can occur by causing air to
be trapped in the heat exchanger. If the boiler system has a diaphragm
expansion tank and the boiler temperatures are being changed, resize the
expansion tank.
If installing on city water supply, a properly sized
thermal expansion tank is required with the water
heater and should be installed as set fo rth in the product installation
manual. Contact your water supplier or local plumbing inspector for
additional information.
Prevent pressure build-up in any existing internal
tankless coil. Do not plug incoming or outgoing
tappings in the internal tankless coil plate. Leave the coil in the boiler and
leave system connections open to prevent pressure build-up.
or, in the absence of local codes, with the National Electrical Code, ANSI/
NFPA 70. Electrical supply must come from the boiler side of boiler's
emergency shut-off switch in order to prevent unsafe boiler operation.
boiler so that leaking will not result in a dry boiler which if the boiler
continues to fire, will cause an explosion hazard.
zone or feed boiler water directly through the coil as dangerous
over-heating will result.
If the thermostat is not
another downstream fixture, as it will damage this unit. A vacuum breaker
should be installed to avoid damaging the liner. Damage to the unit and
leakage can occur if a vacuum breaker is not installed.
during times of non-use.
regarding any steps you may wish to take to safely disinfect your home's
plumbing system.
poisonous substance. To avoid seepage or leakage of glycol to
surfaces where humans or animals can ingest it, use glycol only in
double-walled units, so that any leaks will most likely be released to
the atmosphere. However, a leak to a surface area may still occur,
so any use of glycol must be monitored closely and humans and
animals should be protected from contact with the unit.
units or elements. Any contaminants in the baseboard units will
contaminate the potable water in the water heater and also adversely
affect its performance.
hangers or other hardware into the exterior of the tank.
-2-
Electrocution hazard. The water heater must be
electrically grounded in accordance with local codes
If not installed by the boiler manufacturer, install a
low water cut-off or pressure reducing valve on your
This unit must be installed as a separate heating
zone. Do not connect this unit to an existing heating
Do not drain this appliance before shutting off the
supply valve and opening the relief valve or
As in all plumbing products and water storage
vessels, bacteria can grow in this Product, especially
Consult your local plumbing professional
USE GLYCOL ONLY WITH DOUBLE- WALLED
HEAT EXCHANGER
MODELS.
Do not connect the water heater domestic
supply with baseboard or other space heating
Do not drill, puncture or otherwise penetrate
the steel outer tank shell. Do not screw pipe
Glycol is a