Ice-O-Matic CIM0320 Technical & Service Manual page 8

Elevation series cube ice maker. cim modular cubers
Table of Contents

Advertisement

ELEVATION SERIES CIM CUBERS
Route the refrigerant lines through the roof
opening. Follow straight line routing whenever
possible. Any excess tubing MUST remain inside
the building. Spiral the excess length of pre-
charged tubing inside the building. Use a
horizontal spiral to avoid any traps in the lines.
Have the roofing contractor seal the holes in the
roof per local codes.
The following remote ice makers incorporate the Mixing Valve in the Condenser. This configuration
allows up to a 100 foot calculated remote line set run. Reference the diagram on the next page to calculate
the maximum 100 ft. line set run. Maximum actual line set run is limited to 100 ft. Add 1/4 oz. of
refrigerant for each actual foot from 75 to 100 ft. actual line set run.
CIM Machine Model Number Remote Condenser Model Number
CIM0835/0836/0837
CIM1135/1136/1137
Verify the CIM machine is compatible with the remote condenser.
For more information contact your Ice-O-Matic distributor.
CIM0520/530
CIM0525/535
CIM0636
CIM1126
REMOTE CONDENSER GUIDELINES
CAUTION: The couplings on the sets of pre-charged
lines are self sealing when installed properly.
Carefully follow the instructions in the Remote
Condenser manual.
VRC1001B/RCA1001
VRC1061B/RCA1061
VRC1061B/RCA1061
VRC1061B/RCA1061
VRC1061B/RCA1061
VRC1061B/RCA1061
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cim1136

Table of Contents