User's manual | Vision™ Combi steamers I 7 MAINTENANCE
CLEANING THE AIR FILTER
The combi steamer has an auxiliary fan for cooling the area where the
electrical connection and control electronics are located. Cooling air is
drawn through the air filter, which is located at the bottom of the control
panel, and escapes through a hole in the back of the appliance. For
effective cooling, it is necessary for the air filter to be regularly cleaned ever
3  months. In the event of heavy soiling, it is necessary to clean the filter
more frequently. We recommend checking the filter at least once a month.
The filter is located on the bottom left side of the combi steamer. Simply
pull it out and wash it thoroughly with warm, soapy water. After cleaning,
allow it to dry.
Slide the filter back
in place.

7.3 YEARLY MAINTENANCE

INSPECTING THE INSTALLATION AND APPLIANCE
After a year of operation, the installation and combi steamer must be
checked. We recommend having this inspection performed by an authorized
service, which will check the installation and appliance according to the
Inspection steps chart below.
INSPECTION STEPS
Check for adherence to the included installation manual
1.
2.
Check that the combi steamer is horizontally level
Check door adjustment
3.
4.
Check appliance's cold water connection
5.
Make sure the water supply pressure is set to 50-70 PSI
6.
Check the angle, min. length and diameter of drain pipe.
7.
Check for the minimum 19 in distance from other heat sources
Check for the minimum 2 in distance from other adjacent
8.
surfaces.
9.
Check the area for free airflow at least 19 in above the appliance.
10. Check that there is enough working space for operation and
maintenance.
11. Check the working order of the water filtration system.
12. Check for adherence to fire regulations
13. Check the appliance's short circuit protection
14. Instruct the customer about the appliance's cleaning and
maintenance conditions
15. Instruct the customer about boiler descaling fundamentals, if the
appliance has a boiler.