Trotec IDE 100 D Operating Manual

Trotec IDE 100 D Operating Manual

Oil heater
Hide thumbs Also See for IDE 100 D:

Advertisement

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D /
IDE 100 D
EN
OPERATING MANUAL
OIL HEATER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec IDE 100 D

  • Page 1 IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D OPERATING MANUAL OIL HEATER...
  • Page 2 Follow the manual Information marked with this symbol indicates that the operating manual must be observed. Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 3: Safety

    • This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation. Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 4 Hold onto the mains plug while pulling the power cable out of the mains socket. Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 5: Information About The Device

    An ignition contact at the injection ignites the fuel, which is then burned in a continuous flame. Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 6 Tank filling level indication Frame Control panel Wheel Air outlet for hot air Fuel pump (IDE 100 D only) Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 7: Transport And Storage

    • 2 x Wheel (IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D only) rings by means of a slotted screwdriver. • 1 x Installation material • 1 x Manual Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 8 The device is now ready for operation. the air outlet opening of the device must be at least 3 m (see figure). Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 9: Operation

    4. Allow the device to cool down completely. Designation Rotary control thermostat ON/OFF switch Operating LED Target value indication Room temperature indication Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 10: Errors And Faults

    – For qualified personnel only! Check the ignition: The distance between the two ignition electrodes should be 4 to 5 mm. Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 11: Maintenance

    ð Ensure the tight fit of the screw and, if required, replace the seal, for otherwise fuel might leak out uncontrollably. 6. Dispose of the fuel according to national regulations. Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 12: Technical Annex

    Wear hearing protection. Excessive noise can lead to hearing loss. Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 13: Disposal

    The fuel oil must be drained from the device and collected. Fuels are to be disposed of according to the national regulations. IDE 100 D Operating manual – oil heater IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D...
  • Page 14 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

This manual is also suitable for:

Ide 20 dIde 50 dIde 60 dIde 30 d

Table of Contents