Motion sensor

Advertisement

1. Apply power to the sensor. Initialization is complete when the LED stops
flashing slowly (about 30 seconds).
2. Turn the microwave sensitivity counterclockwise to reduce the microwave
range (minimum = 16.4' / 5m) and close the sensor.
3. Walk through the detection area and observe the LED.
4. Adjust the microwave range as necessary to meet installation requirements.
Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal
operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature (see
Walk Test Reset above).
Note: During power up and walk test modes the LED is active regardless of the LED Enable/Disable Dip switch setting.
LED
Red
Yellow
Green
Zones / Zones / Zonas / Zonas
Look-down / Basses / Vista Zona 0 /
2
A
Vigilância inferior
18
B
Lower / Courtes / Cercana/ Mais baixas
Intermediate / Intermédiaires / Intermedia /
20
C
Intermédias
Long / Longues / Largo Alcance / Longo
54
D
alcance
- 2 -
Power Up
Walk Test
Normal
Slow
ON
ON
Blink
Alarm
Alarm
ON
ON
OFF
Microwave
Microwave
ON
ON
OFF
PIR
PIR
Fault
Fast
Blink
OFF
OFF