Download Print this page
Honeywell DT8050A Quick Installation Manual

Honeywell DT8050A Quick Installation Manual

Dual tec motion sensor with anti-mask

Advertisement

Quick Links

DRAFT - QUICK INSTALL GUIDE - 12/10/13
DT8050A DUAL TEC
DT8050A DUAL TEC
DT8050A DUAL TEC
DT8050A DUAL TEC
*
* Keep Clear / Tenir à l'écart /
Respetar obligatoriamente /
Manter-se afastado
A
#6 x 1 1/4"
(3.5 mm x 32 mm)
Internal EOL Resistor DIP Switches
Résistance interne EOL commutateur DIP
Interruptores DIP internos EOL Resistor
EOL interno Resistor DIP Switches
ON
EOL
1
KOhm
®
Motion Sensor with Anti-Mask - Quick Installation Guide
®
Motion Sensor with Anti-Mask - Quick Installation Guide (FR)
®
Motion Sensor with Anti-Mask - Quick Installation Guide (SP)
®
Motion Sensor with Anti-Mask - Quick Installation Guide (PG)
B
*
2
2.2 5.6
*
*
(3.5 mm)
X
DT8050A
Antienmascaramiento
ON
ON
ON
EOL
KOhm
OFF
1 2 2.2 5.6
AM LED
MAX
PULL
MW
TO DISABLE
LOOK DOWN
SENSITIVITY
W1
LOOK DOWN
#6
B
A
X
A
B
B
A
Enabled
Activé
Habilitado
Habilitado
Anti-mask
ON
Anti-masque
Anti-máscara
OFF
*Disabled
*Désactivé
*Deshabilitado
*Deshabilitado
Microwave Range Adjustment
Réglage de la portée Hyperfréquence
Ajuste del rango de detección Microondas
Ajuste de Alcance Microondas
*
MAX
MW
MIN
SENSITIVITY
*
Factory default / Réglage usine /
Defecto de fábrica / Padrão de fábrica
B
B
B
*

Advertisement

loading

Summary of Contents for Honeywell DT8050A

  • Page 1 DRAFT - QUICK INSTALL GUIDE - 12/10/13 DT8050A DUAL TEC ® Motion Sensor with Anti-Mask - Quick Installation Guide DT8050A DUAL TEC ® Motion Sensor with Anti-Mask - Quick Installation Guide (FR) DT8050A DUAL TEC ® Motion Sensor with Anti-Mask - Quick Installation Guide (SP) DT8050A DUAL TEC ®...
  • Page 2 Trouble Tamper Alarm Power 0 VDC - V 30 mA 30 mA 30 mA 18 mA supply 1.8 mA max 25 VDC 25 VDC 25 VDC 9 - 15 VDC LED TBL KOhm 2.2 5.6 WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES To connect all three outputs (sensor alarm, tamper and trouble/anti- Control Panel mask) to one zone input: All alarm, tamper and trouble/anti-mask...
  • Page 3 To connect the sensor alarm, tamper and trouble/anti-mask outputs Control Panel to three separate zone inputs: The alarm, tamper and trouble/anti-mask Trouble Zone Tamper Zone Alarm Ground +12V are each wired to a separate zone; the control panel differentiates alarm, Zone Zone Zone...
  • Page 4 2 Corporate Center Drive, Suite 100 Please contact your local authorized Honeywell representative for product warranty information. P.O. Box 9040, Melville, NY 11747 Pour obtenir de l'information sur la garantie de ce produit, veuillez communiquer avec le représentant autorisé de Honeywell de votre région. www.honeywell.com/security Por favor contacte con su distribuidor Honeywell Security para información sobre la garantía del producto.