Download Print this page

Factory Reset - Roland JP-8080 Service Notes

Synthesizer module
Hide thumbs Also See for JP-8080:

Advertisement

JP-8080

FACTORY RESET

(1)Turn the power on.
(2)Press [EDIT].
(3)Press [INIT/UTIL]([BANK 7]) several times to select the
display of Factory Reset.
Factory Reset
ALL
(4)Press [REC]. The message of confirmation appears on the
LCD.
Erase your data
OK? [WRITE/EXIT]
(5)Press [WRITE] to load the factory setting data.
HOW TO UPDATE THE SOFTWARE
The JP-8080 is equipped with a flash memory allowing updates
of the program version from MIDI.
Update disk : 17048696 JP-8080 Ver.UP DISK
WARNING!!
READ THIS BEFORE STARTING THE VERSION UPGRADE:
(1)The JP-8080 might not start up if mistakes are made in the
version upgrade procedure or the power is cut during
operation. Always comply with the procedure listed below
and PLEASE! never turn off the power during operation.
(2)The user data area is used as the job memory during the
version upgrade. This means that user data will be
deleted. Be sure to make a backup copy of the user data
before attempting the version upgrade.
NOTICE:
(1)The software update disk(17048696 JP-8080 Ver.UP
DISK) consists of a floppy disk(3.5inch) and a list of Check-
sum. Obtain the latest version from the service center.
(2)The program is converted and saved as Standard MIDI
Files(SMF). A sequencer that can play SMF data is
required.(e.g. SB-55, XP-50/60/80)
(3)The file names are as follows.
vvv_01.MID
vvv_02.MID
vvv_05.MID
vvv_06.MID
vvv_09.MID
vvv_10.MID
vvv_13.MID
vvv_14.MID
"vvv" indicates the version number.
For example "102" signifies Version 1.02.
Update procedure
(1)Connect the sequencer MIDI-OUT and the JP-8080 MIDI-
IN terminals with the MIDI cable.
(2)Turn on the power while holding down the two [WRITE]
and [PORTAMENTO ON] buttons.
8
[REC]
vvv_03.MID
vvv_04.MID
vvv_07.MID
vvv_08.MID
vvv_11.MID
vvv_12.MID
(3)Press [REC] when the display in Fig.1 appears. You can
quit the version upgrade at this point, by pressing [EXIT].
Check that the display in Fig.2 appears.
Erase USER data!
Sure? [REC/EXIT]
fig 1.
(4)Load the file into sequencer. Load in sequence from
vvv_01.MID.
(5)Play the song. Fig.3 appears on the JP-8080 display.
Check Sum: ****
>>>x [REC/EXIT]
(6)The check sum appears at the end of the song. Check that
it matches the value on the list.
Check Sum: ????
(^_^) [REC/EXIT]
If the value is different, press [EXIT] and repeat steps 5 and
6. (Inquire at your Roland Service center if the value is still
wrong after repeating steps 5 and 6 several times.)
(7)If the value is correct press the [REC] button. Be sure never
to cut off the power while the display in Fig.5 appears.
When loading one file ends, the display in Fig.6 appears.
Now updating..
[Keep power on]
fig. 5
(8)Load the files one at a time, in sequence from
vvv_02.MIDto vvv_14.MID and repeat steps (5) through
(7) from the procedure.
(9)Once all files have been loaded, the display in Fig.6
appears.
Turn the power off and then to make the factory resetting.
Reload the user data from backup copy.
Error1)If an error message appears during play of SMF, turn
off the power and redo from the beginning.
Error2)In step (7) of this procedure, if "Completed" does not
appear within 40 seconds after pressing [REC] or if
the message "Can't update!" appears, then the
version upgrade is a failure. When this occurs you
must replace the main board.
Jul, 1998
Ready to update
[Play SMF]
fig 2.
fig3.
Check this value
fig 4.
Completed
[Play next SMF]
fig. 6

Advertisement

loading