ABB RET615 Product Manual page 53

Relion 615 series. transformer protection and control
Hide thumbs Also See for RET615:
Table of Contents

Advertisement

ABB
Transformer Protection and Control
RET615
Product version: 4.0
The standard configuration determines the I/O hardware and available options.
The example below shows standard configuration "A" with chosen options.
#
Description
4-8
Standard configurations, analog and binary I/O options
Standard configuration descriptions in short:
A = Three-phase transformer di erential protection for two-winding transform -
ers, numerical restricted earth-fault protection for the high-voltage (HV) side,
CB control and optional RTD/mA inputs
B = Three-phase transformer di erential protection for two-winding transform -
ers, numerical restricted earth-fault protection for the low-voltage (LV) side, CB
control, optional RTD/mA inputs
C = Three-phase transformer di erential protection for two-winding transform -
ers, high-impedance based restricted earth-fault protection for the high-voltage
(HV) side, optional RTD/mA inputs
D = Three-phase transformer di erential protection for two-winding transform -
ers, high-impedance based restricted earth-fault protection for the low-voltage
(LV) side, CB control and optional RTD/mA inputs
E = Three-phase transformer di erential protection for two-winding transform -
ers, numerical restricted earth-fault protection for the high-voltage (HV) side,
phase-voltage based protection and measurement functions
F = Three-phase transformer di erential protection for two-winding transform -
ers, numerical restricted earth-fault protection for the low-voltage (LV) side,
phase-voltage based protection and measurement functions and CB control
G = Three-phase transformer di erential protection for two-winding transform -
ers, high-impedance based restricted earth-fault protection for the high-voltage
(HV) side, phase-voltage based protection and measurement functions and CB
control
H = Three-phase transformer di erential protection for two-winding transform -
ers, high-impedance based restricted earth-fault protection for the low-voltage
(LV) side, phase-voltage based protection and measurement functions and CB
control
Std. conf.
I/O options
A
7I (Io 1/5 A) + 8 BI +10 BO
A
7I (Io 1/5 A) + 14 BI + 13 BO
A
7I (Io 1/5 A) + 6 RTD + 2 mA + 8 BI + 10 BO
B
7I (Io 1/5 A) + 8 BI +10 BO
B
7I (Io 1/5 A) + 14 BI + 13 BO
B
7I (Io 1/5 A) + 6 RTD + 2 mA + 8 BI + 10 BO
C
7I (Io 1/5 A) + 8 BI +10 BO
C
7I (Io 1/5 A) + 14 BI + 13 BO
C
7I (Io 1/5 A) + 6 RTD + 2 mA + 8 BI + 10 BO
D
7I (Io 1/5 A) + 8 BI +10 BO
D
7I (Io 1/5 A) + 14 BI + 13 BO
D
7I (Io 1/5 A) + 6 RTD + 2 mA + 8 BI + 10 BO
E
7I (Io 1/5 A) + 5U + 12 BI + 10 BO
F
7I (Io 1/5 A) + 5U + 12 BI + 10 BO
G
7I (Io 1/5 A) + 5U + 12 BI + 10 BO
H
7I (Io 1/5 A) + 5U + 12 BI + 10 BO
GUID-CC2E3ED2-0950-4B81-89B9-E481F9160AEA V3 EN
H B T
A B G B A
B C C 1 B B N 1 X E
ABABA
ABABB
ABGBA
BBABA
BBABB
BBGBA
CBABA
CBABB
CBGBA
DBABA
DBABB
DBGBA
EBCAD
FBCAD
GBCAD
HBCAD
1MRS756891 F
53