Piping Diagram: Indoor Unit - Daikin ERGA04DAV3A Installer's Reference Manual

Daikin altherma - low temperature split
Hide thumbs Also See for ERGA04DAV3A:
Table of Contents

Advertisement

14 Technical data
14.2

Piping diagram: Indoor unit

A
C
a2
f
b2
b1
C
a1
f
A
Water side
B
Refrigerant side
C
Field installed
a1
Space heating water IN
a2
Space heating water OUT
b1
Domestic hot water: cold water IN
b2
Domestic hot water: hot water OUT
c1
Gas refrigerant IN (heating mode; condenser)
c2
Liquid refrigerant OUT (heating mode; condenser)
d1
Liquid refrigerant IN (cooling mode; evaporator)
d2
Gas refrigerant OUT (cooling mode; evaporator)
e
Plate heat exchanger
f
Shut-off valve for service (if equipped)
g
Expansion vessel
h
Magnetic filter/dirt separator
i
Safety valve
j
Air purge
k
Drain valve
l
Pump
m
Flow sensor
n
Backup heater
Installer reference guide
90
j
n
k
M3S
R8T
R5T
f
g
Final English - Tanslations in progress
B1PW
m
R1T
R2T
i
j
R4T
l
h
k
B1PW
Space heating water pressure sensor
B2PR
Refrigerant pressure sensor
M3S
3-way valve (space heating/domestic hot water)
R1T
Thermistor (heat exchanger – water OUT)
R2T
Thermistor (backup heater – water OUT)
R3T
Thermistor (liquid refrigerant)
R4T
Thermistor (heat exchanger – water IN)
R5T, R8T
Thermistor (tank)
Screw connection
Flare connection
Quick coupling
Brazed connection
B
B2PR
d2
c1
e
c2
R3T
d1
k
3D111411
ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA
Daikin Altherma – Low temperature split
4P495248-1 – 2017.12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents