Indoor Unit - Daikin ERGA04DAV3A Installer's Reference Manual

Daikin altherma - low temperature split
Hide thumbs Also See for ERGA04DAV3A:
Table of Contents

Advertisement

3 About the box
2 While handling the unit:
▪ Keep both sides of the sling level.
▪ Keep your back straight.
3 After mounting the unit, remove the sling from the unit by pulling
1 side of the sling.
3.2.3
To remove the accessories from the
outdoor unit
1 Lift the outdoor unit. See
"3.2.2 To handle the outdoor unit" on
page 7.
2 Remove the accessories at the bottom of the package.
a
b
c
a
Outdoor unit installation manual
b
Fluorinated greenhouse gases label
c
Multilingual fluorinated greenhouse gases label
d
Energy label
e
Unit mounting plate
f
Bolts, nuts, washers, spring washers and wire clamp
Installer reference guide
8
d
e
f
ENERG
ENERG
Y
IJA
Y
IJA
IE
IA
IE
IA
Final English - Tanslations in progress
3.3

Indoor unit

3.3.1
To unpack the indoor unit
1
2
3.3.2
To remove the accessories from the
indoor unit
a
b
c
d
e
a
Shut-off valves for space heating water circuit
b
Overpressure bypass valve
c
General safety precautions
d
Addendum book for optional equipment
e
Indoor unit installation manual
f
Operation manual
g
Sealing rings for shut-off valves (space heating water
circuit)
h
Sealing rings for field-supplied shut-off valves (domestic
hot water circuit)
i
Sealing tape for low voltage wiring intake
3.3.3
To handle the indoor unit
Use the handles at the back and at the bottom to carry the unit.
a
a
Handles at the back of the unit
b
Handles at the bottom of the unit. Carefully tilt the unit to
the back so that the handles become visible.
ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA
f
g
h
i
a
b
b
Daikin Altherma – Low temperature split
4P495248-1 – 2017.12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents