INSPECTION
Carefully unpack and inspect your machine for shipping damage. Each unit is tested and thoroughly
inspected before shipment and any damage is the responsibility of the delivering carrier who should
be notified immediately.
WARNING
• Read Instruction Manual before operating this piece of equipment.
• To reduce the risk of fire, use only commercially available floor cleaners and waxes intended for
machine application.
• To reduce the risk of electrical shock, do not expose to rain. Store indoors.
• Do not cross over supply cord, hazard exists when rotating brush passes over cord.
• Electrical motors and components can cause an explosion when operated near volatile materials
and vapors. Do not use this machine near flammable materials such as solvents, thinners, fuels,
grain dust, etc.
ELECTRICAL
(Model MC20115) This floor machine is designed to operate on a standard 15 amp. 120 volt, 60 hz,
AC circuit. Voltages below 105 volt AC or above 125 volts AC could cause serious damage to the
motor.
(Model MC20230) This machine is designed to operate on a standard 16 amp type L fused 230 volt,
50 hz, AC circuit. Voltages below 200 volts AC or above 250 volts AC could cause serious damage
to the motor I.E.C. Class 1.

GROUNDING INSTRUCTIONS

• This floor finishing machine should be grounded while in use to protect the operator from electric
shock. The machine is equipped with a three-prong grounding type attachment plug to fit the proper
grounding type receptacle. The green (or green and yellow) conductor in the cord is the grounding
wire. Never connect this wire to other than the grounding blade.
• Floor finishing machines rated less than 150 volts — If the machine is provided with an attachment
plug as shown in Sketch A it is intended for use on a 120-volt (nominal) circuit. If a properly grounded
receptacle as shown in Sketch A is not available, an adapter as shown in Sketch C is available and
should be installed as shown in Sketch B if the outlet box that houses the receptacle is grounded.
Be sure to fasten the grounding tab with the faceplate screw.